← Oklahoma

Tap water quality report

Mcclain Co Rwd # 8

EPA monitoring tested this supplier for 83 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
21
detected
1,897
people served
31
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
McClain

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

31
health-based violations
397
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2010-12-01 → 2010-12-31
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-04-01 → 2006-06-30
MCL Health-based Resolved 2006-01-01 → 2006-03-31
MCL Health-based Resolved 2006-01-01 → 2006-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
916.2 µg/L 70%
of the EPA limit 1300 µg/L
worst single sample: 1410 µg/L
65/109 SYR4 2012–2019
Lead
0.0079 mg/L 53%
of the EPA limit 0.0150 mg/L
24/24 LCR 2026
Chloroform
13.91 µg/L
No EPA limit set
worst single sample: 14 µg/L
19/19 SYR4 2013–2019
Bromodichloromethane
15.4 µg/L
No EPA limit set
worst single sample: 18.7 µg/L
16/19 SYR4 2013–2019
Dibromochloromethane
11.875 µg/L
No EPA limit set
worst single sample: 14.8 µg/L
14/19 SYR4 2013–2019
Bromoform
4.12 µg/L
No EPA limit set
worst single sample: 4.65 µg/L
11/19 SYR4 2013–2019
Lead
116.1 µg/L 774%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 142 µg/L
11/109 SYR4 2012–2019
Combined Radium (-226 And -228)
2.8655 pCi/L 57%
of the EPA limit 5 pCi/L
worst single sample: 2.96 pCi/L
10/10 SYR4 2015–2017
Gross Alpha, Excl. Radon And U
4.897 pCi/L 33%
of the EPA limit 15 pCi/L
worst single sample: 5.86 pCi/L
10/10 SYR4 2015–2017
Gross Beta Particle Activity
5.631 pCi/L
No EPA limit set
worst single sample: 6.18 pCi/L
10/10 SYR4 2015–2017
TTHM
43.065 µg/L 54%
of the EPA limit 80 µg/L
worst single sample: 50.1 µg/L
8/8 SYR4 2014–2019
Nitrate-Nitrite
545 µg/L 5.5%
of the EPA limit 10000 µg/L
worst single sample: 560 µg/L
7/7 SYR4 2013–2019
Combined Uranium
1.955 µg/L 6.5%
of the EPA limit 30 µg/L
worst single sample: 1.99 µg/L
6/10 SYR4 2015–2017
Barium
145.6 µg/L 7.3%
of the EPA limit 2000 µg/L
worst single sample: 148 µg/L
3/3 SYR4 2013–2017
Fluoride
439 µg/L 11%
of the EPA limit 4000 µg/L
worst single sample: 440 µg/L
3/3 SYR4 2013–2017
Nitrate
560 µg/L 5.6%
of the EPA limit 10000 µg/L
2/4 SYR4 2012–2015
Chromium
10 µg/L 10%
of the EPA limit 100 µg/L
1/3 SYR4 2013–2017
Dibromoacetic Acid
1.54 µg/L
No EPA limit set
1/8 SYR4 2014–2019
Dichloroacetic Acid
2.96 µg/L
No EPA limit set
1/8 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
9.05 µg/L 15%
of the EPA limit 60 µg/L
1/8 SYR4 2014–2019
Trichloroacetic Acid
4.55 µg/L
No EPA limit set
1/8 SYR4 2014–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromateChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCCLAIN CO RWD # 8
Phone
405-449-7700
Email
[email protected]

Frequently asked questions about Mcclain Co Rwd # 8

Is Mcclain Co Rwd # 8 tap water safe to drink?

EPA monitoring detected 21 contaminants in Mcclain Co Rwd # 8's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mcclain Co Rwd # 8's water?

EPA monitoring detected Copper, Lead, Chloroform, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Mcclain Co Rwd # 8 serve?

Mcclain Co Rwd # 8 reports serving 1,897 people in Oklahoma, per its EPA record.

Has Mcclain Co Rwd # 8 had any water quality violations?

The EPA has 397 violations on file for Mcclain Co Rwd # 8, of which 31 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.