← Oklahoma

Tap water quality report

Noble Utilities Authority

EPA monitoring tested this supplier for 109 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
22
detected
5,750
people served
17
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Cleveland

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

17
health-based violations
51
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2015-05-01 → 2015-05-31
MCL Health-based Resolved 2015-05-01 → 2015-05-31
MCL Health-based Resolved 2015-05-01 → 2015-05-31
MCL Health-based Resolved 2015-05-01 → 2015-05-31
MCL Health-based Resolved 2008-09-01 → 2008-09-30
MCL Health-based Resolved 2008-09-01 → 2008-09-30
MCL Health-based Resolved 2008-09-01 → 2008-09-30
MCL Health-based Resolved 2008-09-01 → 2008-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFHXS 0.0071 µg/L 2/10 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
351 µg/L 27%
of the EPA limit 1300 µg/L
worst single sample: 678 µg/L
141/141 SYR4 2012–2019
Nitrate-Nitrite
2046.5 µg/L 20%
of the EPA limit 10000 µg/L
worst single sample: 4220 µg/L
80/80 SYR4 2012–2019
Combined Uranium
6.92 µg/L 23%
of the EPA limit 30 µg/L
worst single sample: 8.1 µg/L
29/29 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
9.7 pCi/L 65%
of the EPA limit 15 pCi/L
worst single sample: 9.71 pCi/L
29/29 SYR4 2012–2019
Barium
399.6 µg/L 20%
of the EPA limit 2000 µg/L
worst single sample: 409 µg/L
25/25 SYR4 2013–2018
Gross Beta Particle Activity
5.4696 pCi/L
No EPA limit set
worst single sample: 5.747 pCi/L
25/29 SYR4 2012–2019
Chromium
19 µg/L 19%
of the EPA limit 100 µg/L
worst single sample: 21.7 µg/L
19/25 SYR4 2013–2018
Combined Radium (-226 And -228)
2.872 pCi/L 57%
of the EPA limit 5 pCi/L
worst single sample: 4.2 pCi/L
17/29 SYR4 2012–2019
Lead
0.0013 mg/L 8.7%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Lithium
24.4 µg/L
No EPA limit set
10/10 UCMR-5 2023
Bromodichloromethane
5.3 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
7/33 SYR4 2012–2019
Dibromochloromethane
5.73 µg/L
No EPA limit set
worst single sample: 6 µg/L
7/33 SYR4 2012–2019
TTHM
16.02 µg/L 20%
of the EPA limit 80 µg/L
worst single sample: 16.5 µg/L
7/7 SYR4 2014–2019
Bromoform
5.45 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
6/33 SYR4 2012–2019
Chloroform
3.225 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
6/33 SYR4 2012–2019
Fluoride
260 µg/L 6.5%
of the EPA limit 4000 µg/L
worst single sample: 270 µg/L
5/25 SYR4 2013–2018
Diquat
0.8550 µg/L 4.3%
of the EPA limit 20 µg/L
worst single sample: 0.9000 µg/L
4/31 SYR4 2018–2019
Total Haloacetic Acids (HAA5)
1.28 µg/L 2.1%
of the EPA limit 60 µg/L
worst single sample: 1.3 µg/L
3/7 SYR4 2014–2019
Dibromoacetic Acid
1.29 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
2/7 SYR4 2014–2019
Dichloroacetic Acid
1.1 µg/L
No EPA limit set
1/7 SYR4 2014–2019
Lead
5.3 µg/L 35%
of the EPA limit 15 µg/L
1/141 SYR4 2012–2019
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NOBLE UTILITIES AUTHORITY
Phone
405-872-9251
Email
[email protected]

Frequently asked questions about Noble Utilities Authority

Is Noble Utilities Authority tap water safe to drink?

EPA monitoring detected 22 contaminants in Noble Utilities Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Noble Utilities Authority's water?

EPA monitoring detected Copper, Nitrate-Nitrite, Combined Uranium, Gross Alpha, Excl. Radon And U, Barium, and others. The full list with the level and data source for each is above.

How many people does Noble Utilities Authority serve?

Noble Utilities Authority reports serving 5,750 people in Oklahoma, per its EPA record.

Has Noble Utilities Authority had any water quality violations?

The EPA has 51 violations on file for Noble Utilities Authority, of which 17 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.