Tap water quality report

Binger Pwa

EPA monitoring tested this supplier for 62 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

62
contaminants tested
18
detected
708
people served
6
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Caddo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
166
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2005-08-01 → 2005-08-31
MCL Health-based Resolved 2005-08-01 → 2005-08-31
MCL Health-based Resolved 2005-08-01 → 2005-08-31
MCL Health-based Resolved 2005-08-01 → 2005-08-31
MR Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2025-07-01
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
133 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 166 µg/L
26/30 SYR4 2012–2018
Lead
0.0060 mg/L 40%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Nitrate-Nitrite
3050 µg/L 31%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
1.698 µg/L 11%
of the EPA limit 15 µg/L
worst single sample: 2.01 µg/L
9/30 SYR4 2012–2018
Dibromochloromethane
5.7475 µg/L
No EPA limit set
worst single sample: 5.94 µg/L
8/9 SYR4 2012–2019
TTHM
11.06 µg/L 14%
of the EPA limit 80 µg/L
8/8 SYR4 2012–2019
Bromoform
2.807 µg/L
No EPA limit set
worst single sample: 2.81 µg/L
7/9 SYR4 2012–2019
Bromodichloromethane
1.555 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
4/9 SYR4 2012–2019
Arsenic
6.6605 µg/L 67%
of the EPA limit 10 µg/L
worst single sample: 6.8 µg/L
2/2 SYR4 2013–2019
Barium
151.75 µg/L 7.6%
of the EPA limit 2000 µg/L
worst single sample: 153 µg/L
2/2 SYR4 2014–2017
Dibromoacetic Acid
1.19 µg/L
No EPA limit set
worst single sample: 1.2 µg/L
2/7 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
3.9835 pCi/L 27%
of the EPA limit 15 pCi/L
worst single sample: 4.03 pCi/L
2/2 SYR4 2012–2018
Antimony, Total
1.56 µg/L 26%
of the EPA limit 6 µg/L
1/2 SYR4 2014–2017
Chloroform
1.01 µg/L
No EPA limit set
1/9 SYR4 2012–2019
Chromium
1.36 µg/L 1.4%
of the EPA limit 100 µg/L
1/2 SYR4 2014–2017
Combined Uranium
1.4 µg/L 4.7%
of the EPA limit 30 µg/L
1/2 SYR4 2012–2018
Gross Beta Particle Activity
1.976 pCi/L
No EPA limit set
1/2 SYR4 2012–2018
Toluene
0.7000 µg/L 0.1%
of the EPA limit 1000 µg/L
1/4 SYR4 2012–2016
44 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAtrazineBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideCombined Radium (-226 And -228)DichloromethaneDalaponDichloroacetic AcidDinosebEthylene DibromideEthylbenzeneFluorideGlyphosateLassoMercuryMonobromoacetic AcidMonochloroacetic AcidPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BINGER PWA
Phone
405-656-2426
Email
[email protected]

Frequently asked questions about Binger Pwa

Is Binger Pwa tap water safe to drink?

EPA monitoring detected 18 contaminants in Binger Pwa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Binger Pwa's water?

EPA monitoring detected Copper, Lead, Nitrate-Nitrite, Lead, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Binger Pwa serve?

Binger Pwa reports serving 708 people in Oklahoma, per its EPA record.

Has Binger Pwa had any water quality violations?

The EPA has 166 violations on file for Binger Pwa, of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.