← Oklahoma

Tap water quality report

Okeene

EPA monitoring tested this supplier for 50 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

50
contaminants tested
21
detected
1,240
people served
7
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Blaine

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
47
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2007-05-01 → 2007-05-31
MCL Health-based Resolved 2007-05-01 → 2007-05-31
MCL Health-based Resolved 2007-05-01 → 2007-05-31
MCL Health-based Resolved 1998-09-01 → 1998-09-30
MCL Health-based Resolved 1998-08-01 → 1998-08-31
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
MON Monitoring Resolved 2024-04-01 → 2024-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromoform
44.26 µg/L
No EPA limit set
worst single sample: 46.6 µg/L
23/23 SYR4 2012–2019
Dibromochloromethane
23.9 µg/L
No EPA limit set
worst single sample: 24.4 µg/L
23/23 SYR4 2012–2019
Bromodichloromethane
8.145 µg/L
No EPA limit set
worst single sample: 9.8 µg/L
22/23 SYR4 2012–2019
Copper
689.25 µg/L 53%
of the EPA limit 1300 µg/L
worst single sample: 827 µg/L
20/20 SYR4 2014–2017
Nitrate-Nitrite
1180 µg/L 12%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Arsenic
9.225 µg/L 92%
of the EPA limit 10 µg/L
worst single sample: 11.1 µg/L
16/65 SYR4 2013–2019
Dibromoacetic Acid
10.535 µg/L
No EPA limit set
worst single sample: 10.6 µg/L
14/14 SYR4 2012–2019
TTHM
64.395 µg/L 80%
of the EPA limit 80 µg/L
worst single sample: 69.4 µg/L
14/14 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.275 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 13.6 µg/L
14/14 SYR4 2012–2019
Lead
0.0035 mg/L 23%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Monobromoacetic Acid
1.96 µg/L
No EPA limit set
worst single sample: 2.12 µg/L
11/14 SYR4 2012–2019
Combined Uranium
2.79 µg/L 9.3%
of the EPA limit 30 µg/L
worst single sample: 2.81 µg/L
9/9 SYR4 2017–2019
Dichloroacetic Acid
2.605 µg/L
No EPA limit set
worst single sample: 3.2 µg/L
8/14 SYR4 2012–2019
Chloroform
1.71 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
7/23 SYR4 2012–2019
Gross Beta Particle Activity
6.805 pCi/L
No EPA limit set
worst single sample: 7.44 pCi/L
6/9 SYR4 2017–2019
Combined Radium (-226 And -228)
3.358 pCi/L 67%
of the EPA limit 5 pCi/L
worst single sample: 3.77 pCi/L
5/9 SYR4 2017–2019
Gross Alpha, Excl. Radon And U
3.314 pCi/L 22%
of the EPA limit 15 pCi/L
worst single sample: 3.35 pCi/L
5/9 SYR4 2017–2019
Lead
36.215 µg/L 241%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 41 µg/L
4/20 SYR4 2014–2017
Xylenes, Total
1.684 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1.8 µg/L
3/9 SYR4 2017–2019
Barium
210.55 µg/L 11%
of the EPA limit 2000 µg/L
worst single sample: 211 µg/L
2/2 SYR4 2014–2019
Fluoride
460 µg/L 12%
of the EPA limit 4000 µg/L
2/2 SYR4 2014–2019
29 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylbenzeneMercuryMonochloroacetic AcidSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
OKEENE
Phone
580-822-3035
Email
[email protected]

Frequently asked questions about Okeene

Is Okeene tap water safe to drink?

EPA monitoring detected 21 contaminants in Okeene's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Okeene's water?

EPA monitoring detected Bromoform, Dibromochloromethane, Bromodichloromethane, Copper, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Okeene serve?

Okeene reports serving 1,240 people in Oklahoma, per its EPA record.

Has Okeene had any water quality violations?

The EPA has 47 violations on file for Okeene, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.