Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfba | 0.0086 µg/L | 4/4 | 2024 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chlorite | 846.3 µg/L 85% of the EPA limit 1000 µg/L
worst single sample: 1390 µg/L | 168/177 | SYR4 | 2015–2019 |
| TTHM | 97.83 µg/L 122% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 117 µg/L | 60/60 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 31.845 µg/L 53% of the EPA limit 60 µg/L
worst single sample: 67.8 µg/L | 60/60 | SYR4 | 2012–2019 |
| Bromodichloromethane | 30.26 µg/L No EPA limit set
worst single sample: 36.5 µg/L | 57/57 | SYR4 | 2012–2019 |
| Chloroform | 43.66 µg/L No EPA limit set
worst single sample: 75.9 µg/L | 57/57 | SYR4 | 2012–2019 |
| Dibromochloromethane | 29.92 µg/L No EPA limit set
worst single sample: 32.8 µg/L | 57/57 | SYR4 | 2012–2019 |
| Bromoform | 16.31 µg/L No EPA limit set
worst single sample: 22.6 µg/L | 55/57 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 6.918 µg/L No EPA limit set
worst single sample: 8.89 µg/L | 55/55 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 15.8 µg/L No EPA limit set
worst single sample: 38 µg/L | 55/55 | SYR4 | 2012–2019 |
| Copper | 278.4 µg/L 21% of the EPA limit 1300 µg/L
worst single sample: 482 µg/L | 53/60 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 9.074 µg/L No EPA limit set
worst single sample: 24 µg/L | 52/55 | SYR4 | 2012–2019 |
| Fluoride | 1072 µg/L 27% of the EPA limit 4000 µg/L
worst single sample: 1100 µg/L | 37/37 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.4055 µg/L No EPA limit set
worst single sample: 2.48 µg/L | 24/55 | SYR4 | 2012–2019 |
| Lead | 0.0060 mg/L 40% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Atrazine | 0.7377 µg/L 25% of the EPA limit 3 µg/L
worst single sample: 0.8190 µg/L | 7/16 | SYR4 | 2018–2019 |
| Monochloroacetic Acid | 4.028 µg/L No EPA limit set
worst single sample: 4.08 µg/L | 3/55 | SYR4 | 2012–2019 |
| Barium | 223.75 µg/L 11% of the EPA limit 2000 µg/L
worst single sample: 225 µg/L | 2/2 | SYR4 | 2017–2019 |
| Nitrate | 110 µg/L 1.1% of the EPA limit 10000 µg/L | 2/2 | SYR4 | 2012 |
| Nitrate-Nitrite | 281.5 µg/L 2.8% of the EPA limit 10000 µg/L
worst single sample: 290 µg/L | 2/7 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 0.2900 pCi/L 5.8% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2017 |
| Gross Alpha, Excl. Radon And U | 1.36 pCi/L 9.1% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2017 |
| Gross Beta Particle Activity | 3.96 pCi/L No EPA limit set | 1/1 | SYR4 | 2017 |
| Lead | 37.4 µg/L 249% of the EPA limit, at the 95th percentile of samples — 15 µg/L | 1/60 | SYR4 | 2013–2019 |
87 contaminants tested, none detected
Utility contact
Frequently asked questions about Perry Water & Light Dept
Is Perry Water & Light Dept tap water safe to drink?
EPA monitoring detected 24 contaminants in Perry Water & Light Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Perry Water & Light Dept's water?
EPA monitoring detected Chlorite, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Perry Water & Light Dept serve?
Perry Water & Light Dept reports serving 5,230 people in Oklahoma, per its EPA record.
Has Perry Water & Light Dept had any water quality violations?
The EPA has 1460 violations on file for Perry Water & Light Dept, of which 507 are health-based (a contaminant limit or required treatment was breached) and 13 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.