← Oklahoma

Tap water quality report

Ponca City Mun Water

EPA monitoring tested this supplier for 109 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
26
detected
27,155
people served
25
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Kay

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

25
health-based violations
67
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2011-04-01 → 2011-04-30
TT Health-based Resolved 2011-04-01 → 2011-04-30
TT Health-based Resolved 2011-04-01 → 2011-04-30
TT Health-based Resolved 2011-04-01 → 2011-04-30
TT Health-based Resolved 2007-05-01 → 2007-05-31
TT Health-based Resolved 2007-05-01 → 2007-05-31
TT Health-based Resolved 2007-05-01 → 2007-05-31
TT Health-based Resolved 2007-05-01 → 2007-05-31
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0053 µg/L 4/4 2024
PFHXS 0.0067 µg/L 4/4 2024
PFOS 0.0081 µg/L 4/4 2024
9Cl-PF3ONS 0.0034 µg/L 1/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
17.78 µg/L
No EPA limit set
worst single sample: 27.7 µg/L
153/153 SYR4 2012–2019
Bromoform
25.84 µg/L
No EPA limit set
worst single sample: 39.2 µg/L
153/153 SYR4 2012–2019
Dibromochloromethane
28.12 µg/L
No EPA limit set
worst single sample: 35.8 µg/L
153/153 SYR4 2012–2019
Chloroform
9.12 µg/L
No EPA limit set
worst single sample: 24.2 µg/L
143/153 SYR4 2012–2019
TTHM
78.65 µg/L 98%
of the EPA limit 80 µg/L
worst single sample: 92.1 µg/L
136/136 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.675 µg/L 23%
of the EPA limit 60 µg/L
worst single sample: 17 µg/L
136/136 SYR4 2012–2019
Dibromoacetic Acid
8.1165 µg/L
No EPA limit set
worst single sample: 10.7 µg/L
124/124 SYR4 2012–2019
Dichloroacetic Acid
4.244 µg/L
No EPA limit set
worst single sample: 7.81 µg/L
113/124 SYR4 2012–2019
Fluoride
930 µg/L 23%
of the EPA limit 4000 µg/L
worst single sample: 1140 µg/L
100/100 SYR4 2012–2019
Copper
602.6 µg/L 46%
of the EPA limit 1300 µg/L
worst single sample: 833 µg/L
88/91 SYR4 2013–2019
Monobromoacetic Acid
1.802 µg/L
No EPA limit set
worst single sample: 2.05 µg/L
57/124 SYR4 2012–2019
Combined Uranium
2.48 µg/L 8.3%
of the EPA limit 30 µg/L
worst single sample: 3.11 µg/L
21/21 SYR4 2013–2018
Gross Beta Particle Activity
7.36 pCi/L
No EPA limit set
worst single sample: 11.4 pCi/L
21/21 SYR4 2013–2018
Trichloroacetic Acid
2.246 µg/L
No EPA limit set
worst single sample: 2.59 µg/L
17/124 SYR4 2012–2019
Nitrate-Nitrite
1010 µg/L 10%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
4.802 pCi/L 32%
of the EPA limit 15 pCi/L
worst single sample: 5.95 pCi/L
15/21 SYR4 2013–2018
Combined Radium (-226 And -228)
1.2195 pCi/L 24%
of the EPA limit 5 pCi/L
worst single sample: 1.46 pCi/L
14/21 SYR4 2013–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Barium
80.75 µg/L 4%
of the EPA limit 2000 µg/L
worst single sample: 92 µg/L
6/6 SYR4 2013–2019
Lithium
19.4 µg/L
No EPA limit set
4/4 UCMR-5 2024
Dichloromethane
0.5800 µg/L 12%
of the EPA limit 5 µg/L
1/29 SYR4 2012–2019
Selenium
5.4 µg/L 11%
of the EPA limit 50 µg/L
1/6 SYR4 2013–2019
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 FtsAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPfmbaPfmpaPFNAPFOAPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PONCA CITY MUN WATER
Phone
580-767-0418
Email
[email protected]

Frequently asked questions about Ponca City Mun Water

Is Ponca City Mun Water tap water safe to drink?

EPA monitoring detected 26 contaminants in Ponca City Mun Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ponca City Mun Water's water?

EPA monitoring detected Bromodichloromethane, Bromoform, Dibromochloromethane, Chloroform, TTHM, and others. The full list with the level and data source for each is above.

How many people does Ponca City Mun Water serve?

Ponca City Mun Water reports serving 27,155 people in Oklahoma, per its EPA record.

Has Ponca City Mun Water had any water quality violations?

The EPA has 67 violations on file for Ponca City Mun Water, of which 25 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.