Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Archived | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-07-01 → 2024-07-31 |
| TT | Health-based | Resolved | 2024-07-01 → 2024-07-31 |
| TT | Health-based | Resolved | 2024-07-01 → 2024-07-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 125 µg/L 156% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 157 µg/L | 141/141 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 71 µg/L 118% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 98.8 µg/L | 141/141 | SYR4 | 2012–2019 |
| Chloroform | 106.35 µg/L No EPA limit set
worst single sample: 136 µg/L | 132/132 | SYR4 | 2012–2019 |
| Bromodichloromethane | 18.15 µg/L No EPA limit set
worst single sample: 22.4 µg/L | 131/132 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 41.82 µg/L No EPA limit set
worst single sample: 57.7 µg/L | 129/129 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 35.73 µg/L No EPA limit set
worst single sample: 50 µg/L | 128/129 | SYR4 | 2012–2019 |
| Copper | 553 µg/L 43% of the EPA limit 1300 µg/L
worst single sample: 1760 µg/L | 126/150 | SYR4 | 2013–2019 |
| Dibromochloromethane | 3.8235 µg/L No EPA limit set
worst single sample: 4.62 µg/L | 92/132 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 8.025 µg/L No EPA limit set
worst single sample: 10.1 µg/L | 28/129 | SYR4 | 2012–2019 |
| Lead | 63.965 µg/L 426% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 77.4 µg/L | 24/150 | SYR4 | 2013–2019 |
| Lead | 0.0036 mg/L 24% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Dibromoacetic Acid | 1.389 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 12/129 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 274 µg/L 2.7% of the EPA limit 10000 µg/L | 6/16 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 2.29665 pCi/L 46% of the EPA limit 5 pCi/L
worst single sample: 2.36 pCi/L | 2/2 | SYR4 | 2016–2017 |
| Gross Beta Particle Activity | 2.8715 pCi/L No EPA limit set
worst single sample: 2.89 pCi/L | 2/2 | SYR4 | 2016–2017 |
| Barium | 54.4 µg/L 2.7% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2012 |
| Bromate | 13.2 µg/L 132% of the EPA limit, at the 95th percentile of samples — 10 µg/L | 1/25 | SYR4 | 2017–2019 |
| Dalapon | 1.29 µg/L 0.6% of the EPA limit 200 µg/L | 1/7 | SYR4 | 2017–2019 |
| Di(2-ethylhexyl) Phthalate | 2.42 µg/L 40% of the EPA limit 6 µg/L | 1/2 | SYR4 | 2017 |
| Gross Alpha, Excl. Radon And U | 0.9900 pCi/L 6.6% of the EPA limit 15 pCi/L | 1/2 | SYR4 | 2016–2017 |
| Picloram | 0.0800 µg/L 0% of the EPA limit 500 µg/L | 1/11 | SYR4 | 2012–2019 |
84 contaminants tested, none detected
Utility contact
Frequently asked questions about Mcalester Pwa
Is Mcalester Pwa tap water safe to drink?
EPA monitoring detected 21 contaminants in Mcalester Pwa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Mcalester Pwa's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Chloroform, Bromodichloromethane, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Mcalester Pwa serve?
Mcalester Pwa reports serving 18,206 people in Oklahoma, per its EPA record.
Has Mcalester Pwa had any water quality violations?
The EPA has 990 violations on file for Mcalester Pwa, of which 925 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.