← Oklahoma

Tap water quality report

Mcalester Pwa

EPA monitoring tested this supplier for 105 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

105
contaminants tested
21
detected
18,206
people served
925
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Pittsburg

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

925
health-based violations
990
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-07-01 → 2024-07-31
TT Health-based Resolved 2024-07-01 → 2024-07-31
TT Health-based Resolved 2024-07-01 → 2024-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
125 µg/L 156%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 157 µg/L
141/141 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
71 µg/L 118%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 98.8 µg/L
141/141 SYR4 2012–2019
Chloroform
106.35 µg/L
No EPA limit set
worst single sample: 136 µg/L
132/132 SYR4 2012–2019
Bromodichloromethane
18.15 µg/L
No EPA limit set
worst single sample: 22.4 µg/L
131/132 SYR4 2012–2019
Trichloroacetic Acid
41.82 µg/L
No EPA limit set
worst single sample: 57.7 µg/L
129/129 SYR4 2012–2019
Dichloroacetic Acid
35.73 µg/L
No EPA limit set
worst single sample: 50 µg/L
128/129 SYR4 2012–2019
Copper
553 µg/L 43%
of the EPA limit 1300 µg/L
worst single sample: 1760 µg/L
126/150 SYR4 2013–2019
Dibromochloromethane
3.8235 µg/L
No EPA limit set
worst single sample: 4.62 µg/L
92/132 SYR4 2012–2019
Monochloroacetic Acid
8.025 µg/L
No EPA limit set
worst single sample: 10.1 µg/L
28/129 SYR4 2012–2019
Lead
63.965 µg/L 426%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 77.4 µg/L
24/150 SYR4 2013–2019
Lead
0.0036 mg/L 24%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Dibromoacetic Acid
1.389 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
12/129 SYR4 2012–2019
Nitrate-Nitrite
274 µg/L 2.7%
of the EPA limit 10000 µg/L
6/16 SYR4 2012–2019
Combined Radium (-226 And -228)
2.29665 pCi/L 46%
of the EPA limit 5 pCi/L
worst single sample: 2.36 pCi/L
2/2 SYR4 2016–2017
Gross Beta Particle Activity
2.8715 pCi/L
No EPA limit set
worst single sample: 2.89 pCi/L
2/2 SYR4 2016–2017
Barium
54.4 µg/L 2.7%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Bromate
13.2 µg/L 132%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
1/25 SYR4 2017–2019
Dalapon
1.29 µg/L 0.6%
of the EPA limit 200 µg/L
1/7 SYR4 2017–2019
Di(2-ethylhexyl) Phthalate
2.42 µg/L 40%
of the EPA limit 6 µg/L
1/2 SYR4 2017
Gross Alpha, Excl. Radon And U
0.9900 pCi/L 6.6%
of the EPA limit 15 pCi/L
1/2 SYR4 2016–2017
Picloram
0.0800 µg/L 0%
of the EPA limit 500 µg/L
1/11 SYR4 2012–2019
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDinosebDiquatEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCALESTER PWA
Phone
918-423-9300
Email
[email protected]

Frequently asked questions about Mcalester Pwa

Is Mcalester Pwa tap water safe to drink?

EPA monitoring detected 21 contaminants in Mcalester Pwa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mcalester Pwa's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Chloroform, Bromodichloromethane, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Mcalester Pwa serve?

Mcalester Pwa reports serving 18,206 people in Oklahoma, per its EPA record.

Has Mcalester Pwa had any water quality violations?

The EPA has 990 violations on file for Mcalester Pwa, of which 925 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.