← Oklahoma

Tap water quality report

Shawnee Municipal Authority

EPA monitoring tested this supplier for 81 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
22
detected
29,990
people served
303
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Pottawatomie

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

303
health-based violations
342
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Archived 2025-10-01 → 2025-12-31
TT Health-based Archived 2025-10-01 → 2025-12-31
TT Health-based Archived 2025-10-01 → 2025-12-31
TT Health-based Archived 2025-07-01 → 2025-09-30
TT Health-based Archived 2025-07-01 → 2025-09-30
TT Health-based Archived 2025-07-01 → 2025-09-30
TT Health-based Archived 2025-04-01 → 2025-06-30
TT Health-based Archived 2025-04-01 → 2025-06-30
TT Health-based Archived 2025-04-01 → 2025-06-30
TT Health-based Archived 2025-01-01 → 2025-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0079 µg/L 4/4 2024
Pfpea 0.0032 µg/L 1/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
47.965 µg/L 60%
of the EPA limit 80 µg/L
worst single sample: 62 µg/L
128/128 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
37.4 µg/L 62%
of the EPA limit 60 µg/L
worst single sample: 56.3 µg/L
126/128 SYR4 2012–2019
Bromodichloromethane
17.215 µg/L
No EPA limit set
worst single sample: 22.4 µg/L
118/118 SYR4 2012–2019
Dibromochloromethane
14.2 µg/L
No EPA limit set
worst single sample: 17.4 µg/L
118/118 SYR4 2012–2019
Chloroform
21.85 µg/L
No EPA limit set
worst single sample: 42.7 µg/L
116/118 SYR4 2012–2019
Dichloroacetic Acid
25.705 µg/L
No EPA limit set
worst single sample: 28.1 µg/L
114/116 SYR4 2012–2019
Chlorite
953.5 µg/L 95%
of the EPA limit 1000 µg/L
worst single sample: 981 µg/L
112/114 SYR4 2012–2019
Dibromoacetic Acid
6.67 µg/L
No EPA limit set
worst single sample: 8.11 µg/L
111/116 SYR4 2012–2019
Trichloroacetic Acid
8.71 µg/L
No EPA limit set
worst single sample: 25.4 µg/L
96/116 SYR4 2012–2019
Bromoform
7.8995 µg/L
No EPA limit set
worst single sample: 10.3 µg/L
90/118 SYR4 2012–2019
Copper
326.55 µg/L 25%
of the EPA limit 1300 µg/L
worst single sample: 638 µg/L
72/90 SYR4 2012–2017
Monochloroacetic Acid
5.404 µg/L
No EPA limit set
worst single sample: 6.06 µg/L
22/116 SYR4 2012–2019
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Nitrate-Nitrite
1320 µg/L 13%
of the EPA limit 10000 µg/L
14/22 SYR4 2012–2019
Lead
24.02 µg/L 160%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 25 µg/L
8/90 SYR4 2012–2017
Monobromoacetic Acid
1.705 µg/L
No EPA limit set
worst single sample: 1.76 µg/L
6/116 SYR4 2012–2019
Gross Beta Particle Activity
5.163 pCi/L
No EPA limit set
worst single sample: 5.2 pCi/L
2/2 SYR4 2013–2014
Barium
144 µg/L 7.2%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Combined Radium (-226 And -228)
0.3200 pCi/L 6.4%
of the EPA limit 5 pCi/L
1/2 SYR4 2013–2014
Gross Alpha, Excl. Radon And U
1.66 pCi/L 11%
of the EPA limit 15 pCi/L
1/2 SYR4 2013–2014
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChromiumCombined UraniumDichloromethaneEthylbenzeneFluorideHfpo-DaMercuryNetfosaaNfdhaNmefosaaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SHAWNEE MUNICIPAL AUTHORITY
Phone
405-273-1960
Email
[email protected]

Frequently asked questions about Shawnee Municipal Authority

Is Shawnee Municipal Authority tap water safe to drink?

EPA monitoring detected 22 contaminants in Shawnee Municipal Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Shawnee Municipal Authority's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Dibromochloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Shawnee Municipal Authority serve?

Shawnee Municipal Authority reports serving 29,990 people in Oklahoma, per its EPA record.

Has Shawnee Municipal Authority had any water quality violations?

The EPA has 342 violations on file for Shawnee Municipal Authority, of which 303 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.