Tap water quality report

Coalgate Pwa

EPA monitoring tested this supplier for 58 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

58
contaminants tested
20
detected
2,005
people served
200
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Coal

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

200
health-based violations
371
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-12-01 → 2024-12-31
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Archived 2023-07-01 → 2023-09-30
TT Health-based Archived 2023-07-01 → 2023-09-30
TT Health-based Archived 2023-07-01 → 2023-09-30
TT Health-based Archived 2023-04-01 → 2023-06-30
TT Health-based Archived 2023-04-01 → 2023-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
23.72 µg/L
No EPA limit set
worst single sample: 25 µg/L
57/57 SYR4 2012–2019
Chloroform
80.96 µg/L
No EPA limit set
worst single sample: 90.2 µg/L
57/57 SYR4 2012–2019
TTHM
105.06 µg/L 131%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 120.7 µg/L
57/57 SYR4 2012–2019
Dibromochloromethane
9.62 µg/L
No EPA limit set
worst single sample: 11.3 µg/L
56/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
44.26 µg/L 74%
of the EPA limit 60 µg/L
worst single sample: 53.9 µg/L
49/57 SYR4 2012–2019
Trichloroacetic Acid
26.45 µg/L
No EPA limit set
worst single sample: 29.6 µg/L
46/57 SYR4 2012–2019
Dichloroacetic Acid
21.04 µg/L
No EPA limit set
worst single sample: 26.6 µg/L
39/57 SYR4 2012–2019
Bromoform
4.03 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
26/57 SYR4 2012–2019
Nitrate-Nitrite
827.5 µg/L 8.3%
of the EPA limit 10000 µg/L
worst single sample: 910 µg/L
26/32 SYR4 2012–2019
Copper
303.85 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 319.99 µg/L
20/20 SYR4 2014–2017
Lead
0.0123 mg/L 82%
of the EPA limit 0.0150 mg/L
16/16 LCR 2026
Monochloroacetic Acid
2.935 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
11/57 SYR4 2012–2019
Dibromoacetic Acid
2.0425 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
6/57 SYR4 2012–2019
Lead
1.125 µg/L 7.5%
of the EPA limit 15 µg/L
worst single sample: 1.14 µg/L
4/20 SYR4 2014–2017
Barium
53.75 µg/L 2.7%
of the EPA limit 2000 µg/L
worst single sample: 58.6 µg/L
3/3 SYR4 2018–2019
Gross Beta Particle Activity
53.422 pCi/L
No EPA limit set
worst single sample: 59.03 pCi/L
3/5 SYR4 2012–2019
Selenium
0.6063 µg/L 1.2%
of the EPA limit 50 µg/L
worst single sample: 0.6070 µg/L
3/3 SYR4 2018–2019
Combined Radium (-226 And -228)
0.5503 pCi/L 11%
of the EPA limit 5 pCi/L
worst single sample: 0.5660 pCi/L
2/5 SYR4 2012–2019
Fluoride
990 µg/L 25%
of the EPA limit 4000 µg/L
1/3 SYR4 2018–2019
Gross Alpha, Excl. Radon And U
2.493 pCi/L 17%
of the EPA limit 15 pCi/L
1/5 SYR4 2012–2019
38 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChromiumCombined UraniumDichloromethaneDalaponDinosebDiquatEthylbenzeneGlyphosateMercuryMonobromoacetic AcidPentachlorophenolPicloramStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
COALGATE PWA
Phone
580-927-3914
Email
[email protected]

Frequently asked questions about Coalgate Pwa

Is Coalgate Pwa tap water safe to drink?

EPA monitoring detected 20 contaminants in Coalgate Pwa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Coalgate Pwa's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Dibromochloromethane, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Coalgate Pwa serve?

Coalgate Pwa reports serving 2,005 people in Oklahoma, per its EPA record.

Has Coalgate Pwa had any water quality violations?

The EPA has 371 violations on file for Coalgate Pwa, of which 200 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.