← New York

Tap water quality report

Palmyra Village

EPA monitoring tested this supplier for 107 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
20
detected
3,580
people served
4
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Wayne

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
43
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2009-10-01 → 2009-10-31
TT Health-based Resolved 2009-10-01 → 2009-10-31
TT Health-based Resolved 2007-09-01 → 2007-09-30
TT Health-based Resolved 2007-09-01 → 2007-09-30
RPT Monitoring Unaddressed 2024-11-16
RPT Monitoring Unaddressed 2024-11-16
MR Monitoring Resolved 2016-07-01
MR Monitoring Resolved 2016-07-01
MR Monitoring Resolved 2016-07-01
MR Monitoring Resolved 2016-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
1000 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1120 µg/L
92/92 SYR4 2012–2019
Bromodichloromethane
15.96 µg/L
No EPA limit set
worst single sample: 17.5 µg/L
63/63 SYR4 2012–2019
Chloroform
63.86 µg/L
No EPA limit set
worst single sample: 78.7 µg/L
63/63 SYR4 2012–2019
Dibromochloromethane
3.955 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
62/62 SYR4 2012–2019
Dichloroacetic Acid
13.14 µg/L
No EPA limit set
worst single sample: 17.8 µg/L
62/62 SYR4 2012–2019
TTHM
81.715 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 94.8 µg/L
62/62 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
30.9 µg/L 52%
of the EPA limit 60 µg/L
worst single sample: 39 µg/L
62/62 SYR4 2012–2019
Trichloroacetic Acid
20.28 µg/L
No EPA limit set
worst single sample: 25.8 µg/L
59/62 SYR4 2012–2019
Lead
0.0022 mg/L 15%
of the EPA limit 0.0150 mg/L
18/18 LCR 2023
Nitrate
329 µg/L 3.3%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Barium
24.115 µg/L 1.2%
of the EPA limit 2000 µg/L
worst single sample: 24.5 µg/L
8/8 SYR4 2012–2019
Monochloroacetic Acid
1.84 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
5/62 SYR4 2012–2019
Nitrate-Nitrite
321.2 µg/L 3.2%
of the EPA limit 10000 µg/L
worst single sample: 329 µg/L
5/5 SYR4 2012–2019
Bromoform
0.6850 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
4/62 SYR4 2012–2019
Copper
82.39 µg/L 6.3%
of the EPA limit 1300 µg/L
1/1 SYR4 2014
Chromium
1.3 µg/L 1.3%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Combined Radium (-226 And -228)
0.5510 pCi/L 11%
of the EPA limit 5 pCi/L
1/1 SYR4 2012
Combined Uranium
0.5140 µg/L 1.7%
of the EPA limit 30 µg/L
1/1 SYR4 2012
Gross Alpha, Excl. Radon And U
0.3444 pCi/L 2.3%
of the EPA limit 15 pCi/L
1/1 SYR4 2012
Gross Beta Particle Activity
0.8420 pCi/L
No EPA limit set
1/1 SYR4 2012
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BIEDA, BRIAN
Phone
315-597-5050
Email
[email protected]

Frequently asked questions about Palmyra Village

Is Palmyra Village tap water safe to drink?

EPA monitoring detected 20 contaminants in Palmyra Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Palmyra Village's water?

EPA monitoring detected Fluoride, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Palmyra Village serve?

Palmyra Village reports serving 3,580 people in New York, per its EPA record.

Has Palmyra Village had any water quality violations?

The EPA has 43 violations on file for Palmyra Village, of which 4 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.