← New York

Tap water quality report

Waterloo Village

EPA monitoring tested this supplier for 106 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
25
detected
7,000
people served
4
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Seneca

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
108
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-05-01 → 2014-05-31
MCL Health-based Resolved 2014-05-01 → 2014-05-31
MCL Health-based Resolved 2014-05-01 → 2014-05-31
MCL Health-based Resolved 2014-05-01 → 2014-05-31
MR Monitoring Resolved 2024-10-01
MR Monitoring Resolved 2024-10-01
MR Monitoring Resolved 2024-10-01
MR Monitoring Archived 2021-01-01 → 2021-12-31
MR Monitoring Archived 2021-01-01 → 2021-12-31
MR Monitoring Resolved 2020-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chlorite
552.5 µg/L 55%
of the EPA limit 1000 µg/L
worst single sample: 641 µg/L
86/93 SYR4 2012–2019
Nitrate
468 µg/L 4.7%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
2.4885 µg/L
No EPA limit set
worst single sample: 2.69 µg/L
14/14 SYR4 2012–2019
Chloroform
1.3915 µg/L
No EPA limit set
worst single sample: 1.45 µg/L
14/14 SYR4 2012–2019
Dibromochloromethane
3.649 µg/L
No EPA limit set
worst single sample: 3.87 µg/L
14/14 SYR4 2012–2019
TTHM
9.5235 µg/L 12%
of the EPA limit 80 µg/L
worst single sample: 9.79 µg/L
14/14 SYR4 2012–2019
Dibromoacetic Acid
5.52 µg/L
No EPA limit set
worst single sample: 6 µg/L
13/14 SYR4 2012–2019
Dichloroacetic Acid
4.476 µg/L
No EPA limit set
worst single sample: 4.89 µg/L
13/14 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.688 µg/L 23%
of the EPA limit 60 µg/L
worst single sample: 13.97 µg/L
13/14 SYR4 2012–2019
Bromoform
2.7835 µg/L
No EPA limit set
worst single sample: 3.13 µg/L
12/14 SYR4 2012–2019
Lead
0.0096 mg/L 64%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Monobromoacetic Acid
4.83 µg/L
No EPA limit set
worst single sample: 5.1 µg/L
7/14 SYR4 2012–2019
Trichloroacetic Acid
0.8190 µg/L
No EPA limit set
worst single sample: 0.8700 µg/L
7/14 SYR4 2012–2019
Barium
29 µg/L 1.5%
of the EPA limit 2000 µg/L
6/8 SYR4 2012–2019
Nitrate-Nitrite
466.4 µg/L 4.7%
of the EPA limit 10000 µg/L
worst single sample: 468 µg/L
5/5 SYR4 2014–2019
Monochloroacetic Acid
3.3605 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
4/14 SYR4 2012–2019
Lithium
13.1 µg/L
No EPA limit set
4/4 UCMR-5 2023
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
3/8 SYR4 2012–2019
Fluoride
119 µg/L 3%
of the EPA limit 4000 µg/L
worst single sample: 120 µg/L
3/8 SYR4 2012–2019
Selenium
1.4 µg/L 2.8%
of the EPA limit 50 µg/L
2/8 SYR4 2012–2019
Antimony, Total
0.4300 µg/L 7.2%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Combined Radium (-226 And -228)
1.34 pCi/L 27%
of the EPA limit 5 pCi/L
1/2 SYR4 2013–2019
Combined Uranium
0.2890 µg/L 1%
of the EPA limit 30 µg/L
1/1 SYR4 2013
Gross Beta Particle Activity
3.7 pCi/L
No EPA limit set
1/1 SYR4 2019
Nitrite
43.7 µg/L 4.4%
of the EPA limit 1000 µg/L
1/5 SYR4 2014–2019
81 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TROUT, DON
Phone
315-539-9331

Frequently asked questions about Waterloo Village

Is Waterloo Village tap water safe to drink?

EPA monitoring detected 25 contaminants in Waterloo Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Waterloo Village's water?

EPA monitoring detected Chlorite, Nitrate, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Waterloo Village serve?

Waterloo Village reports serving 7,000 people in New York, per its EPA record.

Has Waterloo Village had any water quality violations?

The EPA has 108 violations on file for Waterloo Village, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.