← New York

Tap water quality report

Cortlandville Town Water

EPA monitoring tested this supplier for 104 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
18
detected
4,300
people served
3
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Cortland

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
5
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-10-01 → 2018-10-31
MCL Health-based Resolved 1994-08-01 → 1994-08-31
MCL Health-based Resolved 1994-08-01 → 1994-08-31
Other Monitoring Resolved 2000-02-01 → 2000-02-29
MR Monitoring Archived 1995-06-01 → 1995-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFNA 0.0067 µg/L 2/4 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2867.5 µg/L 29%
of the EPA limit 10000 µg/L
worst single sample: 2950 µg/L
32/32 SYR4 2012–2019
Nitrate-Nitrite
2837.5 µg/L 28%
of the EPA limit 10000 µg/L
worst single sample: 2950 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
4.373 µg/L
No EPA limit set
worst single sample: 4.49 µg/L
14/14 SYR4 2013–2019
Chloroform
5.9345 µg/L
No EPA limit set
worst single sample: 6.11 µg/L
14/14 SYR4 2013–2019
Dibromochloromethane
4.0775 µg/L
No EPA limit set
worst single sample: 4.24 µg/L
14/14 SYR4 2013–2019
TTHM
15.58 µg/L 19%
of the EPA limit 80 µg/L
worst single sample: 16.23 µg/L
14/14 SYR4 2013–2019
Bromoform
1.598 µg/L
No EPA limit set
worst single sample: 1.61 µg/L
13/14 SYR4 2013–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
12/12 LCR 2027
Dichloroacetic Acid
1.688 µg/L
No EPA limit set
worst single sample: 1.76 µg/L
10/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
3.5345 µg/L 5.9%
of the EPA limit 60 µg/L
worst single sample: 3.8 µg/L
10/13 SYR4 2013–2019
Dibromoacetic Acid
1.565 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
8/14 SYR4 2013–2019
Barium
47.03 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 48.8 µg/L
4/4 SYR4 2014–2017
Combined Radium (-226 And -228)
1.416 pCi/L 28%
of the EPA limit 5 pCi/L
worst single sample: 1.5 pCi/L
4/4 SYR4 2013–2019
Trichloroacetic Acid
1.75 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
3/14 SYR4 2013–2019
Chromium
1.3 µg/L 1.3%
of the EPA limit 100 µg/L
1/4 SYR4 2014–2017
Gross Beta Particle Activity
0.7590 pCi/L
No EPA limit set
1/1 SYR4 2019
Lithium
9.14 µg/L
No EPA limit set
1/4 UCMR-5 2023
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CONGDON, BRIAN
Phone
607-756-9637
Email
[email protected]

Frequently asked questions about Cortlandville Town Water

Is Cortlandville Town Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Cortlandville Town Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cortlandville Town Water's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Cortlandville Town Water serve?

Cortlandville Town Water reports serving 4,300 people in New York, per its EPA record.

Has Cortlandville Town Water had any water quality violations?

The EPA has 5 violations on file for Cortlandville Town Water, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?