← New York

Tap water quality report

Pinewoods

EPA monitoring tested this supplier for 74 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
15
detected
161
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Chenango

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
26
violations on file
0
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2023-07-01 → 2023-09-30
MON Monitoring Resolved 2023-07-01 → 2023-09-30
MON Monitoring Resolved 2023-07-01 → 2023-09-30
MON Monitoring Resolved 2023-07-01 → 2023-09-30
MON Monitoring Resolved 2022-10-01 → 2022-12-31
MON Monitoring Resolved 2022-10-01 → 2022-12-31
MON Monitoring Resolved 2022-10-01 → 2022-12-31
MON Monitoring Resolved 2022-10-01 → 2022-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.00060 mg/L 4%
of the EPA limit 0.0150 mg/L
12/12 LCR 2024
Nitrate
3650 µg/L 37%
of the EPA limit 10000 µg/L
12/32 SYR4 2012–2019
Barium
875.8 µg/L 44%
of the EPA limit 2000 µg/L
worst single sample: 898 µg/L
7/7 SYR4 2013–2019
Fluoride
400 µg/L 10%
of the EPA limit 4000 µg/L
4/7 SYR4 2013–2019
Nitrate-Nitrite
3555.5 µg/L 36%
of the EPA limit 10000 µg/L
worst single sample: 3650 µg/L
4/8 SYR4 2016–2019
Bromoform
5.186 µg/L
No EPA limit set
worst single sample: 5.22 µg/L
3/3 SYR4 2016–2019
Combined Radium (-226 And -228)
1.5445 pCi/L 31%
of the EPA limit 5 pCi/L
worst single sample: 1.61 pCi/L
2/2 SYR4 2017
Dibromoacetic Acid
1.8985 µg/L
No EPA limit set
worst single sample: 1.95 µg/L
2/2 SYR4 2016–2019
Dibromochloromethane
0.8595 µg/L
No EPA limit set
worst single sample: 0.8600 µg/L
2/2 SYR4 2016–2019
Gross Beta Particle Activity
2.656 pCi/L
No EPA limit set
worst single sample: 2.7 pCi/L
2/2 SYR4 2017
TTHM
6.0625 µg/L 7.6%
of the EPA limit 80 µg/L
worst single sample: 6.08 µg/L
2/2 SYR4 2016–2019
Total Haloacetic Acids (HAA5)
2.9475 µg/L 4.9%
of the EPA limit 60 µg/L
worst single sample: 3 µg/L
2/2 SYR4 2016–2019
Di(2-ethylhexyl) Phthalate
0.7020 µg/L 12%
of the EPA limit 6 µg/L
1/7 SYR4 2013–2019
Monochloroacetic Acid
2 µg/L
No EPA limit set
1/2 SYR4 2016–2019
Toluene
2 µg/L 0.2%
of the EPA limit 1000 µg/L
1/7 SYR4 2013–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BURKE, MARYANNE R
Email
[email protected]

Frequently asked questions about Pinewoods

Is Pinewoods tap water safe to drink?

EPA monitoring detected 15 contaminants in Pinewoods's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pinewoods's water?

EPA monitoring detected Lead, Nitrate, Barium, Fluoride, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Pinewoods serve?

Pinewoods reports serving 161 people in New York, per its EPA record.

Has Pinewoods had any water quality violations?

The EPA has 26 violations on file for Pinewoods, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.