← Nevada

Tap water quality report

Nps Callville Bay

EPA monitoring tested this supplier for 82 contaminants and detected 27. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
27
detected
250
people served
46
health-based violations
Water source
Surface water
Ownership
Federal government
Counties served
Clark

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

46
health-based violations
114
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
MCL Health-based Resolved 2009-10-01 → 2009-12-31
MCL Health-based Resolved 2009-10-01 → 2009-12-31
MCL Health-based Resolved 2009-10-01 → 2009-12-31
MCL Health-based Resolved 2009-10-01 → 2009-12-31
MCL Health-based Resolved 2009-07-01 → 2009-09-30
MCL Health-based Resolved 2009-07-01 → 2009-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
25.285 µg/L
No EPA limit set
worst single sample: 27.3 µg/L
44/45 SYR4 2012–2019
Chloroform
45.195 µg/L
No EPA limit set
worst single sample: 48.8 µg/L
44/45 SYR4 2012–2019
Dibromochloromethane
21.01 µg/L
No EPA limit set
worst single sample: 30.6 µg/L
44/45 SYR4 2012–2019
TTHM
89.54 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 91.7 µg/L
43/45 SYR4 2012–2019
Bromoform
3.814 µg/L
No EPA limit set
worst single sample: 8.18 µg/L
37/45 SYR4 2012–2019
Dibromoacetic Acid
5.644 µg/L
No EPA limit set
worst single sample: 5.83 µg/L
34/34 SYR4 2012–2019
Dichloroacetic Acid
17.62 µg/L
No EPA limit set
worst single sample: 18.6 µg/L
34/34 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
30.005 µg/L 50%
of the EPA limit 60 µg/L
worst single sample: 34.5 µg/L
34/34 SYR4 2012–2019
Trichloroacetic Acid
8.932 µg/L
No EPA limit set
worst single sample: 9.52 µg/L
34/34 SYR4 2012–2019
Nitrate
514 µg/L 5.1%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2018
Fluoride
312.05 µg/L 7.8%
of the EPA limit 4000 µg/L
worst single sample: 317 µg/L
10/10 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Barium
122.2 µg/L 6.1%
of the EPA limit 2000 µg/L
worst single sample: 125 µg/L
9/9 SYR4 2012–2019
Copper
242.6 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 338 µg/L
9/9 SYR4 2012–2019
Selenium
5.606 µg/L 11%
of the EPA limit 50 µg/L
worst single sample: 6.49 µg/L
9/9 SYR4 2012–2019
Arsenic
3.7195 µg/L 37%
of the EPA limit 10 µg/L
worst single sample: 3.94 µg/L
8/9 SYR4 2012–2019
Nitrate-Nitrite
500.8 µg/L 5%
of the EPA limit 10000 µg/L
worst single sample: 514 µg/L
7/7 SYR4 2012–2018
Monobromoacetic Acid
3.1475 µg/L
No EPA limit set
worst single sample: 3.79 µg/L
6/34 SYR4 2012–2019
Monochloroacetic Acid
3.33 µg/L
No EPA limit set
worst single sample: 3.55 µg/L
5/34 SYR4 2012–2019
Chromium
5.5565 µg/L 5.6%
of the EPA limit 100 µg/L
worst single sample: 6.05 µg/L
4/9 SYR4 2012–2019
Dalapon
1.0814 µg/L 0.5%
of the EPA limit 200 µg/L
worst single sample: 1.14 µg/L
3/7 SYR4 2012–2019
Antimony, Total
2.918 µg/L 49%
of the EPA limit 6 µg/L
worst single sample: 3 µg/L
2/9 SYR4 2012–2019
Combined Uranium
4.2185 µg/L 14%
of the EPA limit 30 µg/L
worst single sample: 4.23 µg/L
2/2 SYR4 2013–2016
Xylenes, Total
13.804 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 14.5 µg/L
2/13 SYR4 2012–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Ethylbenzene
1.65 µg/L 0.2%
of the EPA limit 700 µg/L
1/13 SYR4 2012–2019
Gross Beta Particle Activity
1.77 pCi/L
No EPA limit set
1/1 SYR4 2016
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SAMMONS, ART
Email
[email protected]

Frequently asked questions about Nps Callville Bay

Is Nps Callville Bay tap water safe to drink?

EPA monitoring detected 27 contaminants in Nps Callville Bay's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Nps Callville Bay's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Nps Callville Bay serve?

Nps Callville Bay reports serving 250 people in Nevada, per its EPA record.

Has Nps Callville Bay had any water quality violations?

The EPA has 114 violations on file for Nps Callville Bay, of which 46 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.