← Nevada

Tap water quality report

Walker Lake Gid

EPA monitoring tested this supplier for 83 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
22
detected
450
people served
5
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Mineral

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
66
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
MCL Health-based Archived 2004-08-01 → 2004-08-31
MCL Health-based Archived 2004-08-01 → 2004-08-31
MCL Health-based Archived 1998-12-01 → 1998-12-31
MCL Health-based Archived 1998-11-01 → 1998-11-30
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1800 µg/L 18%
of the EPA limit 10000 µg/L
worst single sample: 2000 µg/L
44/44 SYR4 2012–2019
Copper
132 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 220 µg/L
17/18 SYR4 2012–2019
Lead
0.00077 mg/L 5.1%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Combined Uranium
19 µg/L 63%
of the EPA limit 30 µg/L
10/10 SYR4 2012–2018
Fluoride
1600 µg/L 40%
of the EPA limit 4000 µg/L
worst single sample: 1800 µg/L
9/9 SYR4 2012–2018
Nitrate-Nitrite
1230 µg/L 12%
of the EPA limit 10000 µg/L
worst single sample: 1300 µg/L
8/8 SYR4 2012–2018
Gross Beta Particle Activity
10.94 pCi/L
No EPA limit set
worst single sample: 11 pCi/L
7/7 SYR4 2012–2016
Arsenic
12.25 µg/L 123%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 13 µg/L
6/7 SYR4 2012–2018
Combined Radium (-226 And -228)
2.0625 pCi/L 41%
of the EPA limit 5 pCi/L
worst single sample: 2.16 pCi/L
6/6 SYR4 2012–2015
Total Haloacetic Acids (HAA5)
19.8 µg/L 33%
of the EPA limit 60 µg/L
worst single sample: 21 µg/L
5/8 SYR4 2012–2019
Barium
70.85 µg/L 3.5%
of the EPA limit 2000 µg/L
worst single sample: 71 µg/L
4/4 SYR4 2012–2018
Bromoform
65.8 µg/L
No EPA limit set
worst single sample: 70 µg/L
4/15 SYR4 2012–2019
Dibromoacetic Acid
13.04 µg/L
No EPA limit set
worst single sample: 14 µg/L
4/8 SYR4 2012–2019
TTHM
73.8 µg/L 92%
of the EPA limit 80 µg/L
worst single sample: 78 µg/L
4/15 SYR4 2012–2019
Bromodichloromethane
1.38 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
3/15 SYR4 2012–2019
Chromium
2.9 µg/L 2.9%
of the EPA limit 100 µg/L
worst single sample: 3 µg/L
3/4 SYR4 2012–2018
Dibromochloromethane
6.79 µg/L
No EPA limit set
worst single sample: 6.8 µg/L
3/15 SYR4 2012–2019
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
2/8 SYR4 2012–2019
Selenium
12.7 µg/L 25%
of the EPA limit 50 µg/L
worst single sample: 13 µg/L
2/4 SYR4 2012–2018
Lead
3 µg/L 20%
of the EPA limit 15 µg/L
1/14 SYR4 2012–2019
Thallium, Total
0.5000 µg/L 25%
of the EPA limit 2 µg/L
1/5 SYR4 2012–2018
Trichloroacetic Acid
21 µg/L
No EPA limit set
1/8 SYR4 2012–2019
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GRANT, LARRY
Phone
775-316-2512
Email
[email protected]

Frequently asked questions about Walker Lake Gid

Is Walker Lake Gid tap water safe to drink?

EPA monitoring detected 22 contaminants in Walker Lake Gid's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Walker Lake Gid's water?

EPA monitoring detected Nitrate, Copper, Lead, Combined Uranium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Walker Lake Gid serve?

Walker Lake Gid reports serving 450 people in Nevada, per its EPA record.

Has Walker Lake Gid had any water quality violations?

The EPA has 66 violations on file for Walker Lake Gid, of which 5 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.