← Nevada

Tap water quality report

Jean Utility Services Inc

EPA monitoring tested this supplier for 84 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

84
contaminants tested
19
detected
560
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Clark

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31
Other Monitoring Archived 1985-10-31 → 1985-11-30
Other Monitoring Archived 1985-08-31 → 1985-09-30
Other Monitoring Archived 1985-07-31 → 1985-08-30
Other Monitoring Archived 1982-03-31 → 1982-04-30
Other Monitoring Archived 1979-10-31 → 1979-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
8.205 µg/L 82%
of the EPA limit 10 µg/L
worst single sample: 9.2 µg/L
34/34 SYR4 2012–2019
Lead
0.0011 mg/L 7.7%
of the EPA limit 0.0150 mg/L
18/18 LCR 2025
Nitrate
3400 µg/L 34%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Combined Uranium
3.97 µg/L 13%
of the EPA limit 30 µg/L
worst single sample: 4 µg/L
7/7 SYR4 2012–2019
Nitrate-Nitrite
3400 µg/L 34%
of the EPA limit 10000 µg/L
6/6 SYR4 2012–2019
Barium
82.32 µg/L 4.1%
of the EPA limit 2000 µg/L
worst single sample: 82.9 µg/L
5/5 SYR4 2012–2019
Chromium
6.98 µg/L 7%
of the EPA limit 100 µg/L
worst single sample: 7.1 µg/L
5/5 SYR4 2012–2019
Fluoride
471.6 µg/L 12%
of the EPA limit 4000 µg/L
worst single sample: 472 µg/L
5/5 SYR4 2012–2019
Selenium
4.2 µg/L 8.4%
of the EPA limit 50 µg/L
worst single sample: 4.3 µg/L
5/5 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
8.21 pCi/L 55%
of the EPA limit 15 pCi/L
worst single sample: 9 pCi/L
3/3 SYR4 2012–2018
Bromoform
1.765 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
2/3 SYR4 2012–2018
Copper
16.47 µg/L 1.3%
of the EPA limit 1300 µg/L
worst single sample: 17 µg/L
2/5 SYR4 2012–2019
TTHM
2.52 µg/L 3.2%
of the EPA limit 80 µg/L
worst single sample: 2.6 µg/L
2/3 SYR4 2012–2018
Asbestos
0.1700 MFL 2.4%
of the EPA limit 7 MFL
1/1 SYR4 2016
Dibromochloromethane
0.8000 µg/L
No EPA limit set
1/3 SYR4 2012–2018
Gross Beta Particle Activity
5.3 pCi/L
No EPA limit set
1/1 SYR4 2012
Lead
1 µg/L 6.7%
of the EPA limit 15 µg/L
1/5 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
3 µg/L 5%
of the EPA limit 60 µg/L
1/3 SYR4 2012–2018
Trichloroacetic Acid
3 µg/L
No EPA limit set
1/3 SYR4 2012–2018
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
OSBORNE, BUCKSHANE
Phone
702-862-3776
Email
[email protected]

Frequently asked questions about Jean Utility Services Inc

Is Jean Utility Services Inc tap water safe to drink?

EPA monitoring detected 19 contaminants in Jean Utility Services Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Jean Utility Services Inc's water?

EPA monitoring detected Arsenic, Lead, Nitrate, Combined Uranium, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Jean Utility Services Inc serve?

Jean Utility Services Inc reports serving 560 people in Nevada, per its EPA record.

Has Jean Utility Services Inc had any water quality violations?

The EPA has 7 violations on file for Jean Utility Services Inc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.