← Nevada

Tap water quality report

Fallon City of

EPA monitoring tested this supplier for 112 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

112
contaminants tested
19
detected
9,184
people served
28
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Churchill

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

28
health-based violations
201
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2006-12-01 → 2006-12-31
MCL Health-based Resolved 2006-12-01 → 2006-12-31
MCL Health-based Resolved 2006-12-01 → 2006-12-31
MCL Health-based Resolved 2006-12-01 → 2006-12-31
MCL Health-based Resolved 2002-07-01 → 2002-09-30
MCL Health-based Resolved 2002-07-01 → 2002-09-30
MCL Health-based Resolved 2002-07-01 → 2002-09-30
MCL Health-based Resolved 2002-04-01 → 2002-06-30
MCL Health-based Resolved 2002-04-01 → 2002-06-30
MCL Health-based Resolved 2002-04-01 → 2002-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
12 µg/L 120%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 17 µg/L
37/37 SYR4 2012–2019
Nitrate
490 µg/L 4.9%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
11/11 LCR 2024
Dibromochloromethane
4.6 µg/L
No EPA limit set
9/10 SYR4 2012–2019
TTHM
18.4 µg/L 23%
of the EPA limit 80 µg/L
worst single sample: 20 µg/L
9/10 SYR4 2012–2019
Bromoform
12.65 µg/L
No EPA limit set
worst single sample: 13 µg/L
8/9 SYR4 2013–2019
Dibromoacetic Acid
3.93 µg/L
No EPA limit set
worst single sample: 4 µg/L
8/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
4.91 µg/L 8.2%
of the EPA limit 60 µg/L
worst single sample: 5.4 µg/L
8/8 SYR4 2012–2019
Fluoride
685 µg/L 17%
of the EPA limit 4000 µg/L
worst single sample: 700 µg/L
4/4 SYR4 2012–2019
Bromodichloromethane
1.5 µg/L
No EPA limit set
3/10 SYR4 2012–2019
Chromium
4.6 µg/L 4.6%
of the EPA limit 100 µg/L
worst single sample: 5 µg/L
3/4 SYR4 2012–2019
Nitrate-Nitrite
367 µg/L 3.7%
of the EPA limit 10000 µg/L
worst single sample: 370 µg/L
3/4 SYR4 2012–2019
Copper
1 µg/L 0.1%
of the EPA limit 1300 µg/L
2/4 SYR4 2012–2019
Chloroform
0.3900 µg/L
No EPA limit set
2/10 SYR4 2012–2019
Lithium
23 µg/L
No EPA limit set
2/2 UCMR-5 2024
Combined Radium (-226 And -228)
0.2410 pCi/L 4.8%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Gross Beta Particle Activity
5.9 pCi/L
No EPA limit set
1/1 SYR4 2016
Selenium
10 µg/L 20%
of the EPA limit 50 µg/L
1/4 SYR4 2012–2019
Trichloroacetic Acid
3.3 µg/L
No EPA limit set
1/8 SYR4 2012–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NORIEGA, ADRIAN
Phone
775-423-6516
Email
[email protected]

Frequently asked questions about Fallon City of

Is Fallon City of tap water safe to drink?

EPA monitoring detected 19 contaminants in Fallon City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fallon City of's water?

EPA monitoring detected Arsenic, Nitrate, Lead, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Fallon City of serve?

Fallon City of reports serving 9,184 people in Nevada, per its EPA record.

Has Fallon City of had any water quality violations?

The EPA has 201 violations on file for Fallon City of, of which 28 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.