← North Dakota

Tap water quality report

Valley City City of

EPA monitoring tested this supplier for 97 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

97
contaminants tested
23
detected
6,585
people served
27
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Barnes

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

27
health-based violations
27
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MCL Health-based Resolved 2005-07-01 → 2005-09-30
MCL Health-based Resolved 2005-07-01 → 2005-09-30
MCL Health-based Resolved 2005-07-01 → 2005-09-30
MCL Health-based Resolved 2005-07-01 → 2005-09-30
MCL Health-based Resolved 2005-04-01 → 2005-06-30
MCL Health-based Resolved 2005-04-01 → 2005-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
12.024 µg/L
No EPA limit set
worst single sample: 18.73 µg/L
57/57 SYR4 2012–2019
Chloroform
16.32 µg/L
No EPA limit set
worst single sample: 21.69 µg/L
57/57 SYR4 2012–2019
Dibromochloromethane
8.526 µg/L
No EPA limit set
worst single sample: 13.81 µg/L
57/57 SYR4 2012–2019
Dichloroacetic Acid
9.776 µg/L
No EPA limit set
worst single sample: 14.1 µg/L
57/57 SYR4 2012–2019
TTHM
33.868 µg/L 42%
of the EPA limit 80 µg/L
worst single sample: 49.97 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
16.776 µg/L 28%
of the EPA limit 60 µg/L
worst single sample: 21.95 µg/L
57/57 SYR4 2012–2019
Copper
200.25 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 467 µg/L
52/60 SYR4 2012–2018
Dibromoacetic Acid
4.073 µg/L
No EPA limit set
worst single sample: 4.89 µg/L
52/57 SYR4 2012–2019
Trichloroacetic Acid
5.415 µg/L
No EPA limit set
worst single sample: 6.42 µg/L
40/57 SYR4 2012–2019
Bromoform
1.8225 µg/L
No EPA limit set
worst single sample: 2.03 µg/L
36/57 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
18/18 LCR 2024
Lead
10.2945 µg/L 69%
of the EPA limit 15 µg/L
worst single sample: 12.7 µg/L
18/60 SYR4 2012–2018
Nitrate-Nitrite
555.5 µg/L 5.6%
of the EPA limit 10000 µg/L
worst single sample: 560 µg/L
10/10 SYR4 2012–2019
Nitrate
460 µg/L 4.6%
of the EPA limit 10000 µg/L
4/4 SYR4 2016–2019
Lithium
32 µg/L
No EPA limit set
4/4 UCMR-5 2024
Monochloroacetic Acid
2.271 µg/L
No EPA limit set
worst single sample: 2.28 µg/L
2/57 SYR4 2012–2019
Tetrachloroethylene
1.486 µg/L 30%
of the EPA limit 5 µg/L
worst single sample: 1.53 µg/L
2/9 SYR4 2012–2018
Barium
6.63 µg/L 0.3%
of the EPA limit 2000 µg/L
1/1 SYR4 2018
Combined Uranium
1 µg/L 3.3%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Fluoride
763 µg/L 19%
of the EPA limit 4000 µg/L
1/1 SYR4 2018
Nitrite
19 µg/L 1.9%
of the EPA limit 1000 µg/L
1/2 SYR4 2016–2019
Trichloroethylene
1 µg/L 20%
of the EPA limit 5 µg/L
1/8 SYR4 2012–2018
cis-1,2-Dichloroethylene
1.14 µg/L 1.6%
of the EPA limit 70 µg/L
1/8 SYR4 2012–2018
74 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDinosebEndrinEthylbenzeneGross Alpha, Excl. Radon And UHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneThallium, TotalTolueneToxapheneVinyl ChlorideXylenes, TotalO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CRAWFORD, GWEN
Phone
701-845-1700
Email
[email protected]

Frequently asked questions about Valley City City of

Is Valley City City of tap water safe to drink?

EPA monitoring detected 23 contaminants in Valley City City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Valley City City of's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Valley City City of serve?

Valley City City of reports serving 6,585 people in North Dakota, per its EPA record.

Has Valley City City of had any water quality violations?

The EPA has 27 violations on file for Valley City City of, of which 27 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.