← North Dakota

Tap water quality report

Valley City, ND

EPA monitoring detected 25 contaminants across the 2 water suppliers serving Valley City. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

2
water suppliers
11,523
people served
25
contaminants found

What was found in Valley City's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
200.25 µg/L 15%
of the EPA limit 1300 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
Highest in the city: 1065 µg/L — BARNES RURAL WATER DISTRICT · 4,938 people · 2017
2/2 SYR4
Fluoride
763 µg/L 19%
of the EPA limit 4000 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
Highest in the city: 1030 µg/L — BARNES RURAL WATER DISTRICT · 4,938 people · 2018
2/2 SYR4
Nitrate-Nitrite
555.5 µg/L 5.6%
of the EPA limit 10000 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Nitrate
460 µg/L 4.6%
of the EPA limit 10000 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
1/2 SYR4
Lithium
32 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2024
Highest in the city: 93.5 µg/L — BARNES RURAL WATER DISTRICT · 4,938 people · 2025
2/2 UCMR-5
TTHM
33.868 µg/L 42%
of the EPA limit 80 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Nitrite
19 µg/L 1.9%
of the EPA limit 1000 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
1/2 SYR4
Barium
6.63 µg/L 0.3%
of the EPA limit 2000 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
Highest in the city: 17.9 µg/L — BARNES RURAL WATER DISTRICT · 4,938 people · 2018
2/2 SYR4
Total Haloacetic Acids (HAA5)
16.776 µg/L 28%
of the EPA limit 60 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Chloroform
16.32 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Bromodichloromethane
12.024 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Lead
10.2945 µg/L 69%
of the EPA limit 15 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
2/2 SYR4
Dichloroacetic Acid
9.776 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Dibromochloromethane
8.526 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Trichloroacetic Acid
5.415 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Chromium
4.62 µg/L 4.6%
of the EPA limit 100 µg/L
Highest in the city: BARNES RURAL WATER DISTRICT · 4,938 people · 2018
1/2 SYR4
Dibromoacetic Acid
4.073 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Monochloroacetic Acid
2.271 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
2/2 SYR4
Bromoform
1.8225 µg/L
No EPA limit set
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2019
1/2 SYR4
Selenium
1.68 µg/L 3.4%
of the EPA limit 50 µg/L
Highest in the city: BARNES RURAL WATER DISTRICT · 4,938 people · 2018
1/2 SYR4
Tetrachloroethylene
1.486 µg/L 30%
of the EPA limit 5 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
1/2 SYR4
cis-1,2-Dichloroethylene
1.14 µg/L 1.6%
of the EPA limit 70 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
1/2 SYR4
Combined Uranium
1 µg/L 3.3%
of the EPA limit 30 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
1/2 SYR4
Trichloroethylene
1 µg/L 20%
of the EPA limit 5 µg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2018
1/2 SYR4
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: VALLEY CITY CITY OF · 6,585 people · 2024
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Valley City

SupplierPopulation served
VALLEY CITY CITY OF 6,585
BARNES RURAL WATER DISTRICT 4,938

Frequently asked questions about Valley City tap water

Is Valley City tap water safe to drink?

EPA testing detected 25 contaminants in the water serving Valley City. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Valley City?

2 public water suppliers report drinking-water monitoring for Valley City, North Dakota to the EPA. Each is listed above with its population served.

What contaminants are in Valley City's water?

The contaminants EPA monitoring detected in Valley City include Copper, Fluoride, Nitrate-Nitrite, Nitrate, Lithium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.