← North Carolina

Tap water quality report

Seagate I

EPA monitoring tested this supplier for 78 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
13
detected
345
people served
5
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Carteret

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
105
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
MCL Health-based Resolved 2010-11-01 → 2010-11-30
Other Monitoring Resolved 2002-07-01
Other Monitoring Resolved 2002-07-01
Other Monitoring Resolved 2002-07-01
MR Monitoring Resolved 2000-01-01 → 2000-01-31
MR Monitoring Resolved 2000-01-01 → 2000-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
725.4 µg/L 56%
of the EPA limit 1300 µg/L
worst single sample: 1940 µg/L
29/40 SYR4 2012–2017
Fluoride
275 µg/L 6.9%
of the EPA limit 4000 µg/L
worst single sample: 280 µg/L
6/6 SYR4 2012–2018
Chloroform
32.765 µg/L
No EPA limit set
worst single sample: 34 µg/L
2/2 SYR4 2014–2017
Combined Radium (-226 And -228)
2.82 pCi/L 56%
of the EPA limit 5 pCi/L
worst single sample: 2.9 pCi/L
2/4 SYR4 2013–2019
Dalapon
2.92 µg/L 1.5%
of the EPA limit 200 µg/L
worst single sample: 3 µg/L
2/14 SYR4 2012–2019
Dichloroacetic Acid
8.78 µg/L
No EPA limit set
worst single sample: 8.8 µg/L
2/2 SYR4 2014–2017
Gross Beta Particle Activity
12.015 pCi/L
No EPA limit set
worst single sample: 12.1 pCi/L
2/2 SYR4 2016
Lead
6.974 µg/L 46%
of the EPA limit 15 µg/L
worst single sample: 7.1 µg/L
2/40 SYR4 2012–2017
TTHM
34.69 µg/L 43%
of the EPA limit 80 µg/L
worst single sample: 36 µg/L
2/2 SYR4 2014–2017
Total Haloacetic Acids (HAA5)
18.49 µg/L 31%
of the EPA limit 60 µg/L
worst single sample: 19 µg/L
2/2 SYR4 2014–2017
Bromodichloromethane
1.6 µg/L
No EPA limit set
1/2 SYR4 2014–2017
Lead
0.0035 mg/L 23%
of the EPA limit 0.0150 mg/L
1/1 LCR 2025
Trichloroacetic Acid
11 µg/L
No EPA limit set
1/2 SYR4 2014–2017
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KANE, DAVID
Phone
910-779-0794
Email
[email protected]

Frequently asked questions about Seagate I

Is Seagate I tap water safe to drink?

EPA monitoring detected 13 contaminants in Seagate I's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Seagate I's water?

EPA monitoring detected Copper, Fluoride, Chloroform, Combined Radium (-226 And -228), Dalapon, and others. The full list with the level and data source for each is above.

How many people does Seagate I serve?

Seagate I reports serving 345 people in North Carolina, per its EPA record.

Has Seagate I had any water quality violations?

The EPA has 105 violations on file for Seagate I, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.