← North Carolina

Tap water quality report

Moore Co Public Util-Pinehurst

EPA monitoring tested this supplier for 109 contaminants and detected 29. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
29
detected
31,390
people served
22
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Moore

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

22
health-based violations
290
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2006-08-01 → 2006-08-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFHXS 0.0045 µg/L 5/38 2024
PFOS 0.0096 µg/L 4/38 2024
Pfpea 0.0188 µg/L 3/38 2024
Pfhxa 0.0183 µg/L 2/38 2024
PFOA 0.0085 µg/L 2/38 2024
Pfba 0.0105 µg/L 1/38 2024
PFBS 0.0136 µg/L 1/38 2024
Pfhpa 0.0065 µg/L 1/38 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3291.3 µg/L 33%
of the EPA limit 10000 µg/L
worst single sample: 4824 µg/L
118/256 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
50.75 µg/L 85%
of the EPA limit 60 µg/L
worst single sample: 121 µg/L
106/126 SYR4 2012–2019
TTHM
63.6 µg/L 80%
of the EPA limit 80 µg/L
worst single sample: 71 µg/L
105/128 SYR4 2012–2019
Dichloroacetic Acid
30 µg/L
No EPA limit set
worst single sample: 86 µg/L
81/100 SYR4 2013–2019
Chloroform
23.262 µg/L
No EPA limit set
worst single sample: 50 µg/L
79/100 SYR4 2013–2019
Trichloroacetic Acid
9.3 µg/L
No EPA limit set
worst single sample: 27 µg/L
79/100 SYR4 2013–2019
Bromodichloromethane
17.306 µg/L
No EPA limit set
worst single sample: 21 µg/L
75/100 SYR4 2013–2019
Dibromochloromethane
20.775 µg/L
No EPA limit set
worst single sample: 30.44 µg/L
66/100 SYR4 2013–2019
Dibromoacetic Acid
9 µg/L
No EPA limit set
worst single sample: 13 µg/L
61/100 SYR4 2013–2019
Copper
193.54 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 296 µg/L
52/90 SYR4 2012–2018
Nitrate-Nitrite
3113.1 µg/L 31%
of the EPA limit 10000 µg/L
worst single sample: 4393 µg/L
47/112 SYR4 2012–2019
Monobromoacetic Acid
8.1 µg/L
No EPA limit set
worst single sample: 11 µg/L
39/100 SYR4 2013–2019
Bromoform
19.4125 µg/L
No EPA limit set
worst single sample: 23.93 µg/L
36/100 SYR4 2013–2019
Combined Radium (-226 And -228)
4.475 pCi/L 89%
of the EPA limit 5 pCi/L
worst single sample: 4.8 pCi/L
26/27 SYR4 2012–2019
Monochloroacetic Acid
4 µg/L
No EPA limit set
worst single sample: 15 µg/L
24/100 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Gross Alpha, Excl. Radon And U
7.08 pCi/L 47%
of the EPA limit 15 pCi/L
worst single sample: 8.4 pCi/L
9/12 SYR4 2012–2016
Gross Beta Particle Activity
7.2 pCi/L
No EPA limit set
worst single sample: 7.5 pCi/L
4/11 SYR4 2012–2016
Combined Uranium
1.49 µg/L 5%
of the EPA limit 30 µg/L
3/13 SYR4 2012–2019
Lead
8.78465 µg/L 59%
of the EPA limit 15 µg/L
worst single sample: 9 µg/L
2/90 SYR4 2012–2018
Nitrite
1066 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 1000 µg/L
1/112 SYR4 2012–2019
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfdaPfdoaPfeesaPfhpsPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PATNODE, BRIAN
Phone
910-947-4300
Email
[email protected]

Frequently asked questions about Moore Co Public Util-Pinehurst

Is Moore Co Public Util-Pinehurst tap water safe to drink?

EPA monitoring detected 29 contaminants in Moore Co Public Util-Pinehurst's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Moore Co Public Util-Pinehurst's water?

EPA monitoring detected Nitrate, Total Haloacetic Acids (HAA5), TTHM, Dichloroacetic Acid, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Moore Co Public Util-Pinehurst serve?

Moore Co Public Util-Pinehurst reports serving 31,390 people in North Carolina, per its EPA record.

Has Moore Co Public Util-Pinehurst had any water quality violations?

The EPA has 290 violations on file for Moore Co Public Util-Pinehurst, of which 22 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.