← North Carolina

Tap water quality report

Weatherstone S/D

EPA monitoring tested this supplier for 79 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
11
detected
120
people served
4
health-based violations
Water source
SWP
Ownership
Private
Counties served
Cabarrus

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
160
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2002-02-01 → 2002-02-28
MCL Health-based Resolved 2002-02-01 → 2002-02-28
MCL Health-based Resolved 2002-02-01 → 2002-02-28
MCL Health-based Resolved 2002-02-01 → 2002-02-28
MR Monitoring Resolved 2002-12-01 → 2002-12-31
MR Monitoring Resolved 2002-12-01 → 2002-12-31
MR Monitoring Resolved 2002-12-01 → 2002-12-31
MR Monitoring Resolved 2000-05-01 → 2000-05-31
MR Monitoring Resolved 2000-05-01 → 2000-05-31
MR Monitoring Resolved 2000-05-01 → 2000-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
465.9 µg/L 36%
of the EPA limit 1300 µg/L
worst single sample: 601 µg/L
15/20 SYR4 2014–2017
Combined Radium (-226 And -228)
3.78 pCi/L 76%
of the EPA limit 5 pCi/L
worst single sample: 3.8 pCi/L
3/3 SYR4 2013–2019
Fluoride
335 µg/L 8.4%
of the EPA limit 4000 µg/L
worst single sample: 340 µg/L
3/3 SYR4 2012–2018
TTHM
6.54 µg/L 8.2%
of the EPA limit 80 µg/L
worst single sample: 7 µg/L
3/6 SYR4 2013–2019
Chloroform
5.63 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
2/5 SYR4 2015–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
2/2 LCR 2025
Lead
4.697 µg/L 31%
of the EPA limit 15 µg/L
worst single sample: 4.74 µg/L
2/20 SYR4 2014–2017
Bromodichloromethane
1.2 µg/L
No EPA limit set
1/5 SYR4 2015–2019
Dichloroacetic Acid
1.2 µg/L
No EPA limit set
1/5 SYR4 2015–2019
Gross Beta Particle Activity
6.3 pCi/L
No EPA limit set
1/1 SYR4 2013
Trichloroacetic Acid
1.9 µg/L
No EPA limit set
1/5 SYR4 2015–2019
68 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLIRON, BRENT
Phone
919-653-6999
Email
[email protected]

Frequently asked questions about Weatherstone S/D

Is Weatherstone S/D tap water safe to drink?

EPA monitoring detected 11 contaminants in Weatherstone S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Weatherstone S/D's water?

EPA monitoring detected Copper, Combined Radium (-226 And -228), Fluoride, TTHM, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Weatherstone S/D serve?

Weatherstone S/D reports serving 120 people in North Carolina, per its EPA record.

Has Weatherstone S/D had any water quality violations?

The EPA has 160 violations on file for Weatherstone S/D, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.