Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2020-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2020-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2020-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2020-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2020-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2020-01-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2019-01-09 |
| MR | Monitoring | Resolved | 2019-01-09 |
| MR | Monitoring | Resolved | 2019-01-09 |
| MON | Monitoring | Resolved | 2018-12-01 → 2018-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 224 µg/L 17% of the EPA limit 1300 µg/L
worst single sample: 725 µg/L | 25/25 | SYR4 | 2012–2017 |
| Nitrate-Nitrite | 117 µg/L 1.2% of the EPA limit 10000 µg/L
worst single sample: 120 µg/L | 22/32 | SYR4 | 2012–2019 |
| Lead | 15.5 µg/L 103% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 20 µg/L | 16/25 | SYR4 | 2012–2017 |
| Combined Uranium | 5 µg/L 17% of the EPA limit 30 µg/L | 11/12 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 9.9 pCi/L 66% of the EPA limit 15 pCi/L
worst single sample: 10 pCi/L | 11/12 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 7/7 | LCR | 2023 |
| Fluoride | 400 µg/L 10% of the EPA limit 4000 µg/L | 6/6 | SYR4 | 2012–2019 |
| Arsenic | 8.8 µg/L 88% of the EPA limit 10 µg/L
worst single sample: 9 µg/L | 3/6 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 1.635 pCi/L 33% of the EPA limit 5 pCi/L
worst single sample: 1.7 pCi/L | 2/11 | SYR4 | 2012–2016 |
| Gross Beta Particle Activity | 1.1 pCi/L No EPA limit set | 1/10 | SYR4 | 2012–2014 |
57 contaminants tested, none detected
Utility contact
Frequently asked questions about Antler Ridge Homeowners Association
Is Antler Ridge Homeowners Association tap water safe to drink?
EPA monitoring detected 10 contaminants in Antler Ridge Homeowners Association's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Antler Ridge Homeowners Association's water?
EPA monitoring detected Copper, Nitrate-Nitrite, Lead, Combined Uranium, Gross Alpha, Excl. Radon And U, and others. The full list with the level and data source for each is above.
How many people does Antler Ridge Homeowners Association serve?
Antler Ridge Homeowners Association reports serving 50 people in Montana, per its EPA record.
Has Antler Ridge Homeowners Association had any water quality violations?
The EPA has 694 violations on file for Antler Ridge Homeowners Association, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.