Tap water quality report

Methuen Water Dept

EPA monitoring tested this supplier for 95 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

95
contaminants tested
11
detected
53,059
people served
1
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Essex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
46
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1996-07-01 → 1996-07-31
MR Monitoring Addressed 2021-06-01
MR Monitoring Resolved 2015-07-01
MR Monitoring Resolved 2015-07-01
MR Monitoring Resolved 2010-06-01 → 2010-09-30
MR Monitoring Resolved 2010-06-01 → 2010-09-30
MR Monitoring Resolved 2010-06-01 → 2010-09-30
MR Monitoring Resolved 2010-06-01 → 2010-09-30
MR Monitoring Resolved 2010-06-01 → 2010-09-30
MR Monitoring Resolved 2010-06-01 → 2010-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfhxa 0.0040 µg/L 2/4 2024
Pfpea 0.0050 µg/L 2/4 2024
PFOA 0.0040 µg/L 1/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
22.85 µg/L 38%
of the EPA limit 60 µg/L
worst single sample: 33.6 µg/L
124/124 SYR4 2012–2019
TTHM
51.535 µg/L 64%
of the EPA limit 80 µg/L
worst single sample: 59 µg/L
112/112 SYR4 2012–2019
Chlorite
29 µg/L 2.9%
of the EPA limit 1000 µg/L
worst single sample: 31 µg/L
37/246 SYR4 2012–2019
Lead
0.0016 mg/L 11%
of the EPA limit 0.0150 mg/L
18/18 LCR 2025
1,2-Dichloroethane
2.42 µg/L 48%
of the EPA limit 5 µg/L
worst single sample: 2.5 µg/L
2/31 SYR4 2012–2019
Nitrate
339 µg/L 3.4%
of the EPA limit 10000 µg/L
2/12 SYR4 2013–2019
Barium
12.8 µg/L 0.6%
of the EPA limit 2000 µg/L
1/7 SYR4 2012–2019
Gross Beta Particle Activity
6.1 pCi/L
No EPA limit set
1/1 SYR4 2012
84 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MEGAN K WINTOUR
Phone
9789838845
Email
[email protected]

Frequently asked questions about Methuen Water Dept

Is Methuen Water Dept tap water safe to drink?

EPA monitoring detected 11 contaminants in Methuen Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Methuen Water Dept's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Chlorite, Lead, 1,2-Dichloroethane, and others. The full list with the level and data source for each is above.

How many people does Methuen Water Dept serve?

Methuen Water Dept reports serving 53,059 people in Massachusetts, per its EPA record.

Has Methuen Water Dept had any water quality violations?

The EPA has 46 violations on file for Methuen Water Dept, of which 1 is health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.