Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| TT | Health-based | Resolved | 2021-09-19 |
| MCL | Health-based | Resolved | 2010-09-01 → 2010-09-30 |
| MCL | Health-based | Resolved | 2010-09-01 → 2010-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 10.985 µg/L 14% of the EPA limit 80 µg/L
worst single sample: 16.33 µg/L | 111/113 | SYR4 | 2012–2019 |
| Dibromochloromethane | 5.0795 µg/L No EPA limit set
worst single sample: 7.73 µg/L | 110/114 | SYR4 | 2012–2019 |
| Bromoform | 3.309 µg/L No EPA limit set
worst single sample: 7.15 µg/L | 95/114 | SYR4 | 2012–2019 |
| Bromodichloromethane | 2.44 µg/L No EPA limit set
worst single sample: 4.2 µg/L | 93/114 | SYR4 | 2012–2019 |
| Chloroform | 1.316 µg/L No EPA limit set
worst single sample: 2 µg/L | 53/114 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 3.045 µg/L 5.1% of the EPA limit 60 µg/L
worst single sample: 7.06 µg/L | 52/117 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.6 µg/L No EPA limit set
worst single sample: 1.7 µg/L | 51/117 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 1500 µg/L 15% of the EPA limit 10000 µg/L
worst single sample: 1900 µg/L | 50/74 | SYR4 | 2012–2019 |
| Lead | 2.275 µg/L 15% of the EPA limit 15 µg/L
worst single sample: 23 µg/L | 26/82 | SYR4 | 2014–2018 |
| Dichloroacetic Acid | 1.16 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 25/117 | SYR4 | 2012–2019 |
| Fluoride | 180 µg/L 4.5% of the EPA limit 4000 µg/L
worst single sample: 200 µg/L | 25/27 | SYR4 | 2012–2018 |
| Barium | 158.5 µg/L 7.9% of the EPA limit 2000 µg/L
worst single sample: 460 µg/L | 22/31 | SYR4 | 2012–2018 |
| Copper | 56.5 µg/L 4.3% of the EPA limit 1300 µg/L
worst single sample: 100 µg/L | 16/82 | SYR4 | 2014–2018 |
| Combined Radium (-226 And -228) | 2.1855 pCi/L 44% of the EPA limit 5 pCi/L
worst single sample: 2.53 pCi/L | 14/24 | SYR4 | 2015–2019 |
| Gross Beta Particle Activity | 3.9115 pCi/L No EPA limit set
worst single sample: 3.97 pCi/L | 14/27 | SYR4 | 2012–2018 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2023 |
| Di(2-ethylhexyl) Phthalate | 2.7975 µg/L 47% of the EPA limit 6 µg/L
worst single sample: 3.45 µg/L | 6/28 | SYR4 | 2012–2018 |
| Monobromoacetic Acid | 0.4725 µg/L No EPA limit set
worst single sample: 0.5100 µg/L | 6/117 | SYR4 | 2012–2019 |
| Beryllium, Total | 0.5680 µg/L 14% of the EPA limit 4 µg/L
worst single sample: 0.5700 µg/L | 3/31 | SYR4 | 2012–2018 |
| Cadmium | 3.477 µg/L 70% of the EPA limit 5 µg/L
worst single sample: 3.8 µg/L | 3/31 | SYR4 | 2012–2018 |
| Benzene | 0.9690 µg/L 19% of the EPA limit 5 µg/L
worst single sample: 1 µg/L | 2/30 | SYR4 | 2012–2018 |
| Selenium | 0.8090 µg/L 1.6% of the EPA limit 50 µg/L
worst single sample: 0.8200 µg/L | 2/31 | SYR4 | 2012–2018 |
| Thallium, Total | 37.11 µg/L 1856% of the EPA limit, at the 95th percentile of samples — 2 µg/L
worst single sample: 39 µg/L | 2/33 | SYR4 | 2012–2018 |
| Arsenic | 0.5200 µg/L 5.2% of the EPA limit 10 µg/L | 1/33 | SYR4 | 2012–2018 |
| Trichloroacetic Acid | 7.06 µg/L No EPA limit set | 1/117 | SYR4 | 2012–2019 |
85 contaminants tested, none detected
Utility contact
Frequently asked questions about City of Minden Water
Is City of Minden Water tap water safe to drink?
EPA monitoring detected 25 contaminants in City of Minden Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in City of Minden Water's water?
EPA monitoring detected TTHM, Dibromochloromethane, Bromoform, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does City of Minden Water serve?
City of Minden Water reports serving 16,281 people in Louisiana, per its EPA record.
Has City of Minden Water had any water quality violations?
The EPA has 39 violations on file for City of Minden Water, of which 26 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.