Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
| TT | Health-based | Resolved | 2022-10-07 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromoform | 210.3 µg/L No EPA limit set
worst single sample: 223 µg/L | 48/48 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 30.575 µg/L No EPA limit set
worst single sample: 34.3 µg/L | 48/48 | SYR4 | 2012–2019 |
| Dibromochloromethane | 46.35 µg/L No EPA limit set
worst single sample: 50.1 µg/L | 48/48 | SYR4 | 2012–2019 |
| TTHM | 255.424 µg/L 319% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 271.8 µg/L | 48/48 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 42.015 µg/L 70% of the EPA limit 60 µg/L
worst single sample: 45.3 µg/L | 48/48 | SYR4 | 2012–2019 |
| Bromodichloromethane | 9.3935 µg/L No EPA limit set
worst single sample: 10.2 µg/L | 44/48 | SYR4 | 2012–2019 |
| Chloroform | 3.3925 µg/L No EPA limit set
worst single sample: 3.7 µg/L | 44/48 | SYR4 | 2012–2019 |
| Copper | 480 µg/L 37% of the EPA limit 1300 µg/L
worst single sample: 600 µg/L | 25/34 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 2.9 µg/L No EPA limit set | 20/48 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 6.402 µg/L No EPA limit set
worst single sample: 6.42 µg/L | 19/48 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 5.54 µg/L No EPA limit set
worst single sample: 5.7 µg/L | 17/48 | SYR4 | 2012–2019 |
| Lead | 4.6 µg/L 31% of the EPA limit 15 µg/L
worst single sample: 7 µg/L | 17/34 | SYR4 | 2013–2019 |
| Fluoride | 816.5 µg/L 20% of the EPA limit 4000 µg/L
worst single sample: 820 µg/L | 8/8 | SYR4 | 2014–2017 |
| Lead | 0.0016 mg/L 11% of the EPA limit 0.0150 mg/L | 8/8 | LCR | 2025 |
| Nitrate-Nitrite | 42 µg/L 0.4% of the EPA limit 10000 µg/L | 8/64 | SYR4 | 2012–2019 |
| Barium | 18.25 µg/L 0.9% of the EPA limit 2000 µg/L
worst single sample: 19 µg/L | 4/8 | SYR4 | 2014–2017 |
| Combined Radium (-226 And -228) | 1.0471 pCi/L 21% of the EPA limit 5 pCi/L
worst single sample: 1.06 pCi/L | 4/4 | SYR4 | 2017 |
| Arsenic | 1 µg/L 10% of the EPA limit 10 µg/L | 3/8 | SYR4 | 2014–2017 |
| Dalapon | 2.24 µg/L 1.1% of the EPA limit 200 µg/L | 2/8 | SYR4 | 2014–2017 |
| Di(2-ethylhexyl) Phthalate | 0.7380 µg/L 12% of the EPA limit 6 µg/L
worst single sample: 0.7400 µg/L | 2/8 | SYR4 | 2014–2017 |
| Benzo(A)Pyrene | 0.0710 µg/L 35% of the EPA limit 0.2000 µg/L | 1/8 | SYR4 | 2014–2017 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Rocky Branch Water
Is Rocky Branch Water tap water safe to drink?
EPA monitoring detected 21 contaminants in Rocky Branch Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Rocky Branch Water's water?
EPA monitoring detected Bromoform, Dibromoacetic Acid, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Rocky Branch Water serve?
Rocky Branch Water reports serving 1,650 people in Louisiana, per its EPA record.
Has Rocky Branch Water had any water quality violations?
The EPA has 292 violations on file for Rocky Branch Water, of which 235 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.