Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| TT | Health-based | Resolved | 2025-04-01 |
| MCL | Health-based | Resolved | 2008-08-01 → 2008-08-31 |
| MCL | Health-based | Resolved | 2008-08-01 → 2008-08-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 6.16 µg/L 41% of the EPA limit 15 µg/L
worst single sample: 12 µg/L | 33/51 | SYR4 | 2014–2019 |
| Copper | 700 µg/L 54% of the EPA limit 1300 µg/L
worst single sample: 1200 µg/L | 31/51 | SYR4 | 2014–2019 |
| Nitrate-Nitrite | 682.2 µg/L 6.8% of the EPA limit 10000 µg/L
worst single sample: 1000 µg/L | 28/66 | SYR4 | 2012–2019 |
| Chloroform | 22.2 µg/L No EPA limit set
worst single sample: 24.8 µg/L | 14/14 | SYR4 | 2013–2019 |
| Fluoride | 947 µg/L 24% of the EPA limit 4000 µg/L
worst single sample: 960 µg/L | 14/14 | SYR4 | 2012–2019 |
| TTHM | 64.94 µg/L 81% of the EPA limit 80 µg/L
worst single sample: 66.5 µg/L | 14/14 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 7.76 µg/L No EPA limit set
worst single sample: 8.2 µg/L | 12/14 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 27.195 µg/L 45% of the EPA limit 60 µg/L
worst single sample: 33.3 µg/L | 12/14 | SYR4 | 2013–2019 |
| Bromodichloromethane | 21.35 µg/L No EPA limit set
worst single sample: 21.8 µg/L | 11/14 | SYR4 | 2013–2019 |
| Dibromochloromethane | 20.3 µg/L No EPA limit set
worst single sample: 21.8 µg/L | 11/14 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 7.45 µg/L No EPA limit set
worst single sample: 7.6 µg/L | 11/14 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 8.8 µg/L No EPA limit set
worst single sample: 9.7 µg/L | 11/14 | SYR4 | 2013–2019 |
| Bromoform | 8.045 µg/L No EPA limit set
worst single sample: 8.9 µg/L | 10/14 | SYR4 | 2013–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2023 |
| Barium | 790 µg/L 40% of the EPA limit 2000 µg/L
worst single sample: 1000 µg/L | 8/15 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 15.994 µg/L 267% of the EPA limit, at the 95th percentile of samples — 6 µg/L
worst single sample: 23.54 µg/L | 8/16 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 3.77 pCi/L No EPA limit set
worst single sample: 4 pCi/L | 5/11 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 10.16 µg/L No EPA limit set
worst single sample: 11.8 µg/L | 5/14 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 1.546 pCi/L 31% of the EPA limit 5 pCi/L
worst single sample: 1.6 pCi/L | 4/7 | SYR4 | 2015–2019 |
| Lithium | 23.3 µg/L No EPA limit set | 4/4 | UCMR-5 | 2025 |
| Monobromoacetic Acid | 9.41 µg/L No EPA limit set
worst single sample: 9.8 µg/L | 2/14 | SYR4 | 2013–2019 |
| Selenium | 0.7650 µg/L 1.5% of the EPA limit 50 µg/L
worst single sample: 0.7700 µg/L | 2/15 | SYR4 | 2012–2019 |
| P-Dichlorobenzene | 0.3075 µg/L 0.4% of the EPA limit 75 µg/L
worst single sample: 0.3100 µg/L | 2/13 | SYR4 | 2012–2019 |
| Arsenic | 1 µg/L 10% of the EPA limit 10 µg/L | 1/15 | SYR4 | 2012–2019 |
| Cadmium | 0.9800 µg/L 20% of the EPA limit 5 µg/L | 1/15 | SYR4 | 2012–2019 |
85 contaminants tested, none detected
Utility contact
Frequently asked questions about Savoy Swords Water System Inc
Is Savoy Swords Water System Inc tap water safe to drink?
EPA monitoring detected 25 contaminants in Savoy Swords Water System Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Savoy Swords Water System Inc's water?
EPA monitoring detected Lead, Copper, Nitrate-Nitrite, Chloroform, Fluoride, and others. The full list with the level and data source for each is above.
How many people does Savoy Swords Water System Inc serve?
Savoy Swords Water System Inc reports serving 7,326 people in Louisiana, per its EPA record.
Has Savoy Swords Water System Inc had any water quality violations?
The EPA has 22 violations on file for Savoy Swords Water System Inc, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.