Tap water quality report

Sandy Point 480 Water

EPA monitoring tested this supplier for 82 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
25
detected
654
people served
601
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Natchitoches Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

601
health-based violations
704
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31
MCL Health-based Resolved 2022-10-01 → 2022-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
335.6 µg/L
No EPA limit set
worst single sample: 383 µg/L
45/47 SYR4 2012–2019
Bromodichloromethane
30.65 µg/L
No EPA limit set
worst single sample: 50.9 µg/L
44/47 SYR4 2012–2019
TTHM
392.55 µg/L 491%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 414.8 µg/L
42/44 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
370.1 µg/L 617%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 563 µg/L
38/43 SYR4 2012–2019
Dichloroacetic Acid
155.25 µg/L
No EPA limit set
worst single sample: 246 µg/L
36/43 SYR4 2012–2019
Trichloroacetic Acid
243.25 µg/L
No EPA limit set
worst single sample: 316 µg/L
36/43 SYR4 2012–2019
Dibromochloromethane
7.113 µg/L
No EPA limit set
worst single sample: 7.8 µg/L
27/47 SYR4 2012–2019
Lead
42.5 µg/L 283%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 110 µg/L
19/26 SYR4 2014–2019
Dibromoacetic Acid
2.75 µg/L
No EPA limit set
worst single sample: 5 µg/L
16/43 SYR4 2012–2019
Copper
300 µg/L 23%
of the EPA limit 1300 µg/L
13/20 SYR4 2014–2019
Monochloroacetic Acid
26.94 µg/L
No EPA limit set
worst single sample: 27.9 µg/L
13/43 SYR4 2012–2019
Lead
0.00029 mg/L 1.9%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Dalapon
83.8471 µg/L 42%
of the EPA limit 200 µg/L
worst single sample: 91.811 µg/L
8/15 SYR4 2012–2019
Nitrate-Nitrite
100 µg/L 1%
of the EPA limit 10000 µg/L
8/16 SYR4 2012–2019
Barium
39.8 µg/L 2%
of the EPA limit 2000 µg/L
worst single sample: 42 µg/L
5/8 SYR4 2012–2019
Hexachlorocyclopentadiene
0.1468 µg/L 0.3%
of the EPA limit 50 µg/L
worst single sample: 0.1610 µg/L
5/15 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.8095 µg/L 13%
of the EPA limit 6 µg/L
worst single sample: 0.8500 µg/L
4/14 SYR4 2012–2019
Fluoride
45.7 µg/L 1.1%
of the EPA limit 4000 µg/L
worst single sample: 46 µg/L
4/8 SYR4 2012–2019
Carbon Tetrachloride
0.8005 µg/L 16%
of the EPA limit 5 µg/L
worst single sample: 0.8100 µg/L
2/8 SYR4 2012–2019
Gross Beta Particle Activity
2.614 pCi/L
No EPA limit set
worst single sample: 2.63 pCi/L
2/8 SYR4 2012–2019
Monobromoacetic Acid
3.04 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
2/43 SYR4 2012–2019
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/8 SYR4 2012–2019
Combined Radium (-226 And -228)
0.8680 pCi/L 17%
of the EPA limit 5 pCi/L
1/5 SYR4 2015–2019
Ethylbenzene
0.6100 µg/L 0.1%
of the EPA limit 700 µg/L
1/8 SYR4 2012–2019
Xylenes, Total
1.87 µg/L 0%
of the EPA limit 10000 µg/L
1/8 SYR4 2012–2019
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GUIN, RONALD
Phone
318-875-2934
Email
[email protected]

Frequently asked questions about Sandy Point 480 Water

Is Sandy Point 480 Water tap water safe to drink?

EPA monitoring detected 25 contaminants in Sandy Point 480 Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sandy Point 480 Water's water?

EPA monitoring detected Chloroform, Bromodichloromethane, TTHM, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Sandy Point 480 Water serve?

Sandy Point 480 Water reports serving 654 people in Louisiana, per its EPA record.

Has Sandy Point 480 Water had any water quality violations?

The EPA has 704 violations on file for Sandy Point 480 Water, of which 601 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.