Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
| TT | Health-based | Resolved | 2022-08-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate-Nitrite | 1730 µg/L 17% of the EPA limit 10000 µg/L
worst single sample: 1800 µg/L | 15/15 | SYR4 | 2012–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2025 |
| Lead | 16.2 µg/L 108% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 21 µg/L | 9/18 | SYR4 | 2013–2019 |
| Arsenic | 2 µg/L 20% of the EPA limit 10 µg/L | 6/6 | SYR4 | 2012–2019 |
| Copper | 550 µg/L 42% of the EPA limit 1300 µg/L
worst single sample: 700 µg/L | 6/18 | SYR4 | 2013–2019 |
| Fluoride | 277.5 µg/L 6.9% of the EPA limit 4000 µg/L
worst single sample: 290 µg/L | 6/6 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 6.55 µg/L 11% of the EPA limit 60 µg/L
worst single sample: 7.8 µg/L | 6/14 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 1.337 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 4/14 | SYR4 | 2013–2019 |
| Nitrate | 1700 µg/L 17% of the EPA limit 10000 µg/L | 4/4 | SYR4 | 2019 |
| Di(2-ethylhexyl) Phthalate | 20.47 µg/L 341% of the EPA limit, at the 95th percentile of samples — 6 µg/L
worst single sample: 21.9 µg/L | 3/10 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 5.72 µg/L No EPA limit set
worst single sample: 6.2 µg/L | 3/14 | SYR4 | 2013–2019 |
| Barium | 47.85 µg/L 2.4% of the EPA limit 2000 µg/L
worst single sample: 48 µg/L | 2/6 | SYR4 | 2012–2019 |
| Chloroform | 0.5370 µg/L No EPA limit set
worst single sample: 0.5400 µg/L | 2/14 | SYR4 | 2013–2019 |
| Chromium | 3.77 µg/L 3.8% of the EPA limit 100 µg/L
worst single sample: 3.8 µg/L | 2/6 | SYR4 | 2012–2019 |
| TTHM | 0.5370 µg/L 0.7% of the EPA limit 80 µg/L
worst single sample: 0.5400 µg/L | 2/14 | SYR4 | 2013–2019 |
| P-Dichlorobenzene | 0.6080 µg/L 0.8% of the EPA limit 75 µg/L
worst single sample: 0.6200 µg/L | 2/6 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 0.7590 pCi/L 15% of the EPA limit 5 pCi/L | 1/4 | SYR4 | 2015–2019 |
| Gross Beta Particle Activity | 2.85 pCi/L No EPA limit set | 1/5 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 1.6 µg/L No EPA limit set | 1/14 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 0.3100 µg/L No EPA limit set | 1/14 | SYR4 | 2013–2019 |
64 contaminants tested, none detected
Utility contact
Frequently asked questions about Magnolia-Cottages of Acadiana
Is Magnolia-Cottages of Acadiana tap water safe to drink?
EPA monitoring detected 20 contaminants in Magnolia-Cottages of Acadiana's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Magnolia-Cottages of Acadiana's water?
EPA monitoring detected Nitrate-Nitrite, Lead, Lead, Arsenic, Copper, and others. The full list with the level and data source for each is above.
How many people does Magnolia-Cottages of Acadiana serve?
Magnolia-Cottages of Acadiana reports serving 196 people in Missouri, per its EPA record.
Has Magnolia-Cottages of Acadiana had any water quality violations?
The EPA has 45 violations on file for Magnolia-Cottages of Acadiana, of which 24 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.