← Louisiana

Tap water quality report

Parkland Trailer Park Water

EPA monitoring tested this supplier for 80 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
16
detected
112
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Lafayette Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
37
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1997-01-01 → 1997-01-31
MCL Health-based Archived 1997-01-01 → 1997-01-31
MCL Health-based Archived 1992-06-01 → 1992-06-30
MCL Health-based Archived 1992-06-01 → 1992-06-30
MR Monitoring Unaddressed 2024-10-15
MR Monitoring Resolved 2022-01-22
MR Monitoring Resolved 2022-01-22
MR Monitoring Resolved 2014-09-01 → 2015-08-31
MR Monitoring Resolved 2014-09-01 → 2015-08-31
MR Monitoring Resolved 2014-09-01 → 2015-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
1000 µg/L 10%
of the EPA limit 10000 µg/L
16/20 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
9/9 LCR 2024
Lead
1.85 µg/L 12%
of the EPA limit 15 µg/L
worst single sample: 2 µg/L
4/18 SYR4 2012–2018
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
3/3 SYR4 2012–2018
Copper
280 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 300 µg/L
3/18 SYR4 2012–2018
Fluoride
263 µg/L 6.6%
of the EPA limit 4000 µg/L
worst single sample: 270 µg/L
3/3 SYR4 2012–2018
Monochloroacetic Acid
2.401 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
3/14 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
2.43 µg/L 4.1%
of the EPA limit 60 µg/L
worst single sample: 2.6 µg/L
3/14 SYR4 2012–2019
Chloroform
0.6665 µg/L
No EPA limit set
worst single sample: 0.6700 µg/L
2/14 SYR4 2012–2019
Chromium
5.97 µg/L 6%
of the EPA limit 100 µg/L
worst single sample: 6 µg/L
2/3 SYR4 2012–2018
Gross Beta Particle Activity
3.0445 pCi/L
No EPA limit set
worst single sample: 3.1 pCi/L
2/3 SYR4 2012–2018
TTHM
0.6665 µg/L 0.8%
of the EPA limit 80 µg/L
worst single sample: 0.6700 µg/L
2/14 SYR4 2012–2019
Barium
90 µg/L 4.5%
of the EPA limit 2000 µg/L
1/3 SYR4 2012–2018
Dibromoacetic Acid
0.3800 µg/L
No EPA limit set
1/14 SYR4 2012–2019
Selenium
0.6100 µg/L 1.2%
of the EPA limit 50 µg/L
1/3 SYR4 2012–2018
P-Dichlorobenzene
0.7100 µg/L 0.9%
of the EPA limit 75 µg/L
1/3 SYR4 2012–2018
64 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MANUEL, TERRY
Email
[email protected]

Frequently asked questions about Parkland Trailer Park Water

Is Parkland Trailer Park Water tap water safe to drink?

EPA monitoring detected 16 contaminants in Parkland Trailer Park Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Parkland Trailer Park Water's water?

EPA monitoring detected Nitrate-Nitrite, Lead, Lead, Arsenic, Copper, and others. The full list with the level and data source for each is above.

How many people does Parkland Trailer Park Water serve?

Parkland Trailer Park Water reports serving 112 people in Louisiana, per its EPA record.

Has Parkland Trailer Park Water had any water quality violations?

The EPA has 37 violations on file for Parkland Trailer Park Water, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.