← Louisiana

Tap water quality report

Monterey Rural Water System Inc

EPA monitoring tested this supplier for 112 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

112
contaminants tested
26
detected
5,250
people served
26
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Concordia Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

26
health-based violations
30
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
TT Health-based Resolved 2019-11-19
MCL Health-based Archived 1991-07-01 → 1991-07-31
MCL Health-based Archived 1991-07-01 → 1991-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
8 µg/L 53%
of the EPA limit 15 µg/L
worst single sample: 14 µg/L
40/68 SYR4 2013–2019
Copper
700 µg/L 54%
of the EPA limit 1300 µg/L
worst single sample: 800 µg/L
38/68 SYR4 2013–2019
Dibromoacetic Acid
5.75 µg/L
No EPA limit set
worst single sample: 8 µg/L
26/30 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
11.1 µg/L 19%
of the EPA limit 60 µg/L
worst single sample: 27.2 µg/L
26/30 SYR4 2013–2019
Combined Radium (-226 And -228)
25.96 pCi/L 519%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 34.3 pCi/L
25/29 SYR4 2016–2019
TTHM
50.65 µg/L 63%
of the EPA limit 80 µg/L
worst single sample: 95.6 µg/L
22/30 SYR4 2013–2019
Barium
2700 µg/L 135%
of the EPA limit, at the 95th percentile of samples — 2000 µg/L
worst single sample: 5000 µg/L
21/27 SYR4 2012–2019
Bromoform
36.3 µg/L
No EPA limit set
worst single sample: 64.3 µg/L
21/30 SYR4 2013–2019
Dibromochloromethane
13.065 µg/L
No EPA limit set
worst single sample: 23.8 µg/L
20/30 SYR4 2013–2019
Bromodichloromethane
3.915 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
18/30 SYR4 2013–2019
Dichloroacetic Acid
2.895 µg/L
No EPA limit set
worst single sample: 4 µg/L
14/30 SYR4 2013–2019
Gross Beta Particle Activity
32.78 pCi/L
No EPA limit set
worst single sample: 41.9 pCi/L
13/20 SYR4 2014–2019
Trichloroacetic Acid
1.434 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
13/30 SYR4 2013–2019
Lead
0.0093 mg/L 62%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Chloroform
1.665 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
10/30 SYR4 2013–2019
Monobromoacetic Acid
1.985 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
8/30 SYR4 2013–2019
Fluoride
157.5 µg/L 3.9%
of the EPA limit 4000 µg/L
worst single sample: 160 µg/L
6/12 SYR4 2013–2019
Arsenic
2.85 µg/L 29%
of the EPA limit 10 µg/L
worst single sample: 3 µg/L
4/12 SYR4 2013–2019
Dalapon
7.61 µg/L 3.8%
of the EPA limit 200 µg/L
3/12 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
13.12 pCi/L 87%
of the EPA limit 15 pCi/L
worst single sample: 13.8 pCi/L
3/4 SYR4 2014–2016
Hexachlorobenzene
0.7380 µg/L 74%
of the EPA limit 1 µg/L
worst single sample: 0.8100 µg/L
3/12 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
0.5590 µg/L 9.3%
of the EPA limit 6 µg/L
worst single sample: 0.5600 µg/L
2/12 SYR4 2013–2019
Lithium
17.4 µg/L
No EPA limit set
2/2 UCMR-5 2025
Chromium
10 µg/L 10%
of the EPA limit 100 µg/L
1/13 SYR4 2013–2019
Monochloroacetic Acid
19.1 µg/L
No EPA limit set
1/30 SYR4 2013–2019
Selenium
7.2 µg/L 14%
of the EPA limit 50 µg/L
1/12 SYR4 2013–2019
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitrate-NitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SANDERS, MILTON
Phone
318-386-2232
Email
[email protected]

Frequently asked questions about Monterey Rural Water System Inc

Is Monterey Rural Water System Inc tap water safe to drink?

EPA monitoring detected 26 contaminants in Monterey Rural Water System Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Monterey Rural Water System Inc's water?

EPA monitoring detected Lead, Copper, Dibromoacetic Acid, Total Haloacetic Acids (HAA5), Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.

How many people does Monterey Rural Water System Inc serve?

Monterey Rural Water System Inc reports serving 5,250 people in Louisiana, per its EPA record.

Has Monterey Rural Water System Inc had any water quality violations?

The EPA has 30 violations on file for Monterey Rural Water System Inc, of which 26 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.