← Louisiana

Tap water quality report

Four Forks Water

EPA monitoring tested this supplier for 82 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

82
contaminants tested
19
detected
609
people served
7
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Caddo Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
55
violations on file
5
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-11-19
TT Health-based Unaddressed 2025-11-19
TT Health-based Addressed 2024-10-17
TT Health-based Resolved 2017-07-11
TT Health-based Resolved 2017-07-11
TT Health-based Resolved 2017-07-11
TT Health-based Resolved 2017-07-11
Other Monitoring Unaddressed 2026-01-06
RPT Monitoring Addressed 2024-10-17
Other Monitoring Resolved 2015-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
3 µg/L 20%
of the EPA limit 15 µg/L
worst single sample: 24 µg/L
61/63 SYR4 2013–2019
Copper
300 µg/L 23%
of the EPA limit 1300 µg/L
31/63 SYR4 2013–2019
Chloroform
4.86 µg/L
No EPA limit set
worst single sample: 5.43 µg/L
13/13 SYR4 2012–2019
TTHM
30.16 µg/L 38%
of the EPA limit 80 µg/L
worst single sample: 31.3 µg/L
13/13 SYR4 2012–2019
Bromodichloromethane
9.3 µg/L
No EPA limit set
worst single sample: 9.45 µg/L
11/13 SYR4 2012–2019
Dibromochloromethane
13.45 µg/L
No EPA limit set
worst single sample: 13.8 µg/L
11/13 SYR4 2012–2019
Bromoform
5.23 µg/L
No EPA limit set
worst single sample: 5.5 µg/L
10/13 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
9/9 LCR 2023
Dibromoacetic Acid
6.4465 µg/L
No EPA limit set
worst single sample: 6.59 µg/L
8/13 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
8.9 µg/L 15%
of the EPA limit 60 µg/L
worst single sample: 9.6 µg/L
8/13 SYR4 2012–2019
Dichloroacetic Acid
2.475 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
6/13 SYR4 2012–2019
Nitrate-Nitrite
30 µg/L 0.3%
of the EPA limit 10000 µg/L
6/22 SYR4 2012–2019
Trichloroacetic Acid
1.3 µg/L
No EPA limit set
6/13 SYR4 2012–2019
Fluoride
168.5 µg/L 4.2%
of the EPA limit 4000 µg/L
worst single sample: 170 µg/L
4/4 SYR4 2013–2019
Barium
43.2 µg/L 2.2%
of the EPA limit 2000 µg/L
worst single sample: 44 µg/L
3/4 SYR4 2013–2019
Chromium
5.932 µg/L 5.9%
of the EPA limit 100 µg/L
worst single sample: 6.2 µg/L
2/4 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.22 pCi/L 8.1%
of the EPA limit 15 pCi/L
1/4 SYR4 2013–2019
Gross Beta Particle Activity
0.8750 pCi/L
No EPA limit set
1/4 SYR4 2013–2019
Monobromoacetic Acid
0.5200 µg/L
No EPA limit set
1/13 SYR4 2012–2019
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CALDWELL, CARLIN
Phone
318-458-5718
Email
[email protected]

Frequently asked questions about Four Forks Water

Is Four Forks Water tap water safe to drink?

EPA monitoring detected 19 contaminants in Four Forks Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Four Forks Water's water?

EPA monitoring detected Lead, Copper, Chloroform, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Four Forks Water serve?

Four Forks Water reports serving 609 people in Louisiana, per its EPA record.

Has Four Forks Water had any water quality violations?

The EPA has 55 violations on file for Four Forks Water, of which 7 are health-based (a contaminant limit or required treatment was breached) and 5 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.