← Louisiana

Tap water quality report

Pine Trailer Park

EPA monitoring tested this supplier for 81 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
15
detected
60
people served
29
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Ascension Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

29
health-based violations
701
violations on file
26
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-03-13
TT Health-based Unaddressed 2025-03-13
TT Health-based Unaddressed 2025-03-13
TT Health-based Unaddressed 2025-03-13
TT Health-based Unaddressed 2025-03-13
TT Health-based Unaddressed 2025-03-13
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2022-06-08
TT Health-based Resolved 2022-06-08
TT Health-based Resolved 2022-06-08

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
6.675 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 8.4 µg/L
16/24 SYR4 2017–2019
Dichloroacetic Acid
2.26 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
14/24 SYR4 2017–2019
Dibromoacetic Acid
2.42 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
12/24 SYR4 2017–2019
Trichloroacetic Acid
1.95 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
11/24 SYR4 2017–2019
Bromodichloromethane
5.54 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
9/24 SYR4 2017–2019
Chloroform
8.68 µg/L
No EPA limit set
worst single sample: 11.8 µg/L
9/24 SYR4 2017–2019
TTHM
20.82 µg/L 26%
of the EPA limit 80 µg/L
worst single sample: 22.7 µg/L
9/24 SYR4 2017–2019
Dibromochloromethane
5.425 µg/L
No EPA limit set
worst single sample: 6.3 µg/L
8/24 SYR4 2017–2019
Lead
4.8 µg/L 32%
of the EPA limit 15 µg/L
worst single sample: 5 µg/L
5/14 SYR4 2017–2019
Bromoform
2.05 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
3/24 SYR4 2017–2019
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
3/3 SYR4 2014–2019
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
3/3 LCR 2020
Monochloroacetic Acid
1.7505 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
2/24 SYR4 2017–2019
Di(2-ethylhexyl) Phthalate
0.7400 µg/L 12%
of the EPA limit 6 µg/L
1/3 SYR4 2014–2019
Gross Beta Particle Activity
1.67 pCi/L
No EPA limit set
1/3 SYR4 2014–2019
66 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitrate-NitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
STAFFORD, CALVIN
Phone
225-715-6425
Email
[email protected]

Frequently asked questions about Pine Trailer Park

Is Pine Trailer Park tap water safe to drink?

EPA monitoring detected 15 contaminants in Pine Trailer Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pine Trailer Park's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), Dichloroacetic Acid, Dibromoacetic Acid, Trichloroacetic Acid, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Pine Trailer Park serve?

Pine Trailer Park reports serving 60 people in Louisiana, per its EPA record.

Has Pine Trailer Park had any water quality violations?

The EPA has 701 violations on file for Pine Trailer Park, of which 29 are health-based (a contaminant limit or required treatment was breached) and 26 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.