← Kentucky

Tap water quality report

Ledbetter Water District

EPA monitoring tested this supplier for 103 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

103
contaminants tested
14
detected
2,729
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Livingston

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
488
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
Other Monitoring Resolved 2025-03-16
Other Monitoring Resolved 2025-03-16
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0058 µg/L 1/6 2025
PFOA 0.0043 µg/L 1/6 2025
PFOS 0.0062 µg/L 1/6 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
97.18 µg/L 121%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 110 µg/L
33/33 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
57.4 µg/L 96%
of the EPA limit 60 µg/L
worst single sample: 59 µg/L
33/33 SYR4 2012–2019
Copper
472 µg/L 36%
of the EPA limit 1300 µg/L
worst single sample: 550 µg/L
28/58 SYR4 2012–2019
Lead
0.0012 mg/L 8%
of the EPA limit 0.0150 mg/L
17/17 LCR 2025
Lead
114 µg/L 760%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 210 µg/L
11/50 SYR4 2013–2019
Fluoride
1265 µg/L 32%
of the EPA limit 4000 µg/L
worst single sample: 1400 µg/L
10/10 SYR4 2012–2019
Barium
42.85 µg/L 2.1%
of the EPA limit 2000 µg/L
worst single sample: 43 µg/L
2/2 SYR4 2014–2017
Combined Radium (-226 And -228)
1.79 pCi/L 36%
of the EPA limit 5 pCi/L
worst single sample: 1.8 pCi/L
2/2 SYR4 2016–2017
Gross Alpha, Excl. Radon And U
10.24 pCi/L 68%
of the EPA limit 15 pCi/L
worst single sample: 10.7 pCi/L
2/2 SYR4 2016–2017
Gross Beta Particle Activity
9.4 pCi/L
No EPA limit set
1/2 SYR4 2016–2017
Mercury
0.2400 µg/L 12%
of the EPA limit 2 µg/L
1/2 SYR4 2014–2017
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaNitrateNitrate-NitriteNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FOX, ALAN
Phone
270-898-3236
Email
[email protected]

Frequently asked questions about Ledbetter Water District

Is Ledbetter Water District tap water safe to drink?

EPA monitoring detected 14 contaminants in Ledbetter Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ledbetter Water District's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Lead, Lead, and others. The full list with the level and data source for each is above.

How many people does Ledbetter Water District serve?

Ledbetter Water District reports serving 2,729 people in Kentucky, per its EPA record.

Has Ledbetter Water District had any water quality violations?

The EPA has 488 violations on file for Ledbetter Water District, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.