← Indiana

Tap water quality report

Huntingburg Municipal Water

EPA monitoring tested this supplier for 108 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
21
detected
6,526
people served
17
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Dubois

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

17
health-based violations
195
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2024-01-01 → 2024-03-31
MCL Health-based Resolved 2015-01-01 → 2015-03-31
MCL Health-based Resolved 2015-01-01 → 2015-03-31
MCL Health-based Resolved 2015-01-01 → 2015-03-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
81.6 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 102.8 µg/L
101/101 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
69.3 µg/L 116%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 138.5 µg/L
101/101 SYR4 2012–2019
Copper
306.2 µg/L 24%
of the EPA limit 1300 µg/L
worst single sample: 1010 µg/L
19/20 SYR4 2017
Nitrate
591 µg/L 5.9%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Lead
0.0114 mg/L 76%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Fluoride
700.7 µg/L 18%
of the EPA limit 4000 µg/L
worst single sample: 707 µg/L
8/8 SYR4 2012–2019
Atrazine
0.4370 µg/L 15%
of the EPA limit 3 µg/L
worst single sample: 0.5000 µg/L
7/31 SYR4 2012–2019
Lead
18.975 µg/L 127%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 24 µg/L
6/20 SYR4 2017
Arsenic
2.09 µg/L 21%
of the EPA limit 10 µg/L
worst single sample: 2.2 µg/L
3/8 SYR4 2012–2019
Chloroform
30.42 µg/L
No EPA limit set
worst single sample: 30.7 µg/L
3/3 SYR4 2012–2014
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
2/8 SYR4 2012–2019
Barium
175.757 µg/L 8.8%
of the EPA limit 2000 µg/L
worst single sample: 185 µg/L
2/8 SYR4 2012–2019
Bromodichloromethane
3.055 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
2/3 SYR4 2012–2014
Nitrate-Nitrite
577.45 µg/L 5.8%
of the EPA limit 10000 µg/L
worst single sample: 591 µg/L
2/2 SYR4 2016–2019
Bromoform
5.7 µg/L
No EPA limit set
1/3 SYR4 2012–2014
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.9000 µg/L 15%
of the EPA limit 6 µg/L
1/31 SYR4 2012–2019
Dibromochloromethane
0.5000 µg/L
No EPA limit set
1/3 SYR4 2012–2014
Gross Beta Particle Activity
3.4 pCi/L
No EPA limit set
1/1 SYR4 2017
Methoxychlor
0.6500 µg/L 1.6%
of the EPA limit 40 µg/L
1/28 SYR4 2012–2019
Selenium
1.4 µg/L 2.8%
of the EPA limit 50 µg/L
1/8 SYR4 2012–2019
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
AUSTIN, JERRY
Phone
812-683-4280
Email
[email protected]

Frequently asked questions about Huntingburg Municipal Water

Is Huntingburg Municipal Water tap water safe to drink?

EPA monitoring detected 21 contaminants in Huntingburg Municipal Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Huntingburg Municipal Water's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Huntingburg Municipal Water serve?

Huntingburg Municipal Water reports serving 6,526 people in Indiana, per its EPA record.

Has Huntingburg Municipal Water had any water quality violations?

The EPA has 195 violations on file for Huntingburg Municipal Water, of which 17 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.