← Indiana

Tap water quality report

Sellersburg Water Department

EPA monitoring tested this supplier for 107 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
18
detected
15,655
people served
10
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Clark

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
221
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-08-01 → 2008-08-31
MCL Health-based Resolved 2008-08-01 → 2008-08-31
MCL Health-based Resolved 2008-08-01 → 2008-08-31
MCL Health-based Resolved 2008-08-01 → 2008-08-31
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOA 0.0040 µg/L 1/2 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
677.5 µg/L 52%
of the EPA limit 1300 µg/L
worst single sample: 976 µg/L
170/170 SYR4 2016–2019
Lead
9.24 µg/L 62%
of the EPA limit 15 µg/L
worst single sample: 14.2 µg/L
65/170 SYR4 2016–2019
TTHM
51.3 µg/L 64%
of the EPA limit 80 µg/L
worst single sample: 61 µg/L
38/38 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
23.02 µg/L 38%
of the EPA limit 60 µg/L
worst single sample: 24 µg/L
35/38 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Nitrate
1630 µg/L 16%
of the EPA limit 10000 µg/L
16/20 SYR4 2012–2019
Bromodichloromethane
5.5 µg/L
No EPA limit set
6/6 SYR4 2014–2019
Chloroform
5.375 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
6/6 SYR4 2014–2019
Dibromochloromethane
5.02 µg/L
No EPA limit set
worst single sample: 5.1 µg/L
5/6 SYR4 2014–2019
Bromoform
1.1 µg/L
No EPA limit set
4/6 SYR4 2014–2019
Fluoride
980.9 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 997 µg/L
3/3 SYR4 2015–2019
Gross Alpha, Excl. Radon And U
11.58 pCi/L 77%
of the EPA limit 15 pCi/L
worst single sample: 12.4 pCi/L
3/6 SYR4 2014–2017
Barium
24.86 µg/L 1.2%
of the EPA limit 2000 µg/L
worst single sample: 25.2 µg/L
2/3 SYR4 2014–2019
Gross Beta Particle Activity
5.351 pCi/L
No EPA limit set
worst single sample: 5.4 pCi/L
2/4 SYR4 2016–2017
Arsenic
1.4 µg/L 14%
of the EPA limit 10 µg/L
1/3 SYR4 2014–2019
Combined Radium (-226 And -228)
0.0900 pCi/L 1.8%
of the EPA limit 5 pCi/L
1/1 SYR4 2017
Combined Uranium
0.2235 µg/L 0.7%
of the EPA limit 30 µg/L
1/6 SYR4 2014–2017
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitrate-NitriteNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
STARNES, SHANNON
Phone
502-376-4517
Email
[email protected]

Frequently asked questions about Sellersburg Water Department

Is Sellersburg Water Department tap water safe to drink?

EPA monitoring detected 18 contaminants in Sellersburg Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sellersburg Water Department's water?

EPA monitoring detected Copper, Lead, TTHM, Total Haloacetic Acids (HAA5), Lead, and others. The full list with the level and data source for each is above.

How many people does Sellersburg Water Department serve?

Sellersburg Water Department reports serving 15,655 people in Indiana, per its EPA record.

Has Sellersburg Water Department had any water quality violations?

The EPA has 221 violations on file for Sellersburg Water Department, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.