Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Resolved | 2012-01-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2011-01-01 → 2011-12-31 |
| MR | Monitoring | Resolved | 2011-01-01 → 2011-12-31 |
| MR | Monitoring | Resolved | 2011-01-01 → 2011-12-31 |
| MR | Monitoring | Resolved | 2011-01-01 → 2011-12-31 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfpea | 0.0033 µg/L | 1/34 | 2023 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 5000 µg/L 50% of the EPA limit 10000 µg/L
worst single sample: 5300 µg/L | 634/634 | SYR4 | 2012–2019 |
| Fluoride | 248 µg/L 6.2% of the EPA limit 4000 µg/L
worst single sample: 280 µg/L | 285/290 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 4900 µg/L 49% of the EPA limit 10000 µg/L
worst single sample: 5300 µg/L | 276/276 | SYR4 | 2012–2019 |
| TTHM | 4.925 µg/L 6.2% of the EPA limit 80 µg/L
worst single sample: 36 µg/L | 128/199 | SYR4 | 2012–2019 |
| Bromoform | 4.42 µg/L No EPA limit set
worst single sample: 29 µg/L | 127/198 | SYR4 | 2012–2019 |
| Copper | 85 µg/L 6.5% of the EPA limit 1300 µg/L
worst single sample: 430 µg/L | 45/60 | SYR4 | 2013–2019 |
| Barium | 4.785 µg/L 0.2% of the EPA limit 2000 µg/L
worst single sample: 10 µg/L | 42/60 | SYR4 | 2013–2019 |
| Chromium | 9.05 µg/L 9.1% of the EPA limit 100 µg/L
worst single sample: 10 µg/L | 40/60 | SYR4 | 2013–2019 |
| Lead | 3.91 µg/L 26% of the EPA limit 15 µg/L
worst single sample: 4.9 µg/L | 12/60 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2018 |
| Dibromochloromethane | 3.97 µg/L No EPA limit set
worst single sample: 4.9 µg/L | 7/198 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 3.98 pCi/L No EPA limit set
worst single sample: 4.04 pCi/L | 6/40 | SYR4 | 2013–2019 |
| 1,2-DIBROMO-3-CHLOROPROPANE | 0.0290 µg/L 14% of the EPA limit 0.2000 µg/L
worst single sample: 0.0300 µg/L | 5/294 | SYR4 | 2012–2019 |
| Bromodichloromethane | 2.76 µg/L No EPA limit set
worst single sample: 3 µg/L | 4/199 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 0.3760 pCi/L 2.5% of the EPA limit 15 pCi/L
worst single sample: 0.4000 pCi/L | 4/39 | SYR4 | 2013–2018 |
| Selenium | 7.605 µg/L 15% of the EPA limit 50 µg/L
worst single sample: 7.8 µg/L | 4/60 | SYR4 | 2013–2019 |
| Chloroform | 17.22 µg/L No EPA limit set
worst single sample: 19 µg/L | 3/199 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1 µg/L No EPA limit set | 1/93 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 1.2 µg/L No EPA limit set | 1/93 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 3.2 µg/L 5.3% of the EPA limit 60 µg/L | 1/94 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 1 µg/L No EPA limit set | 1/93 | SYR4 | 2012–2019 |
92 contaminants tested, none detected
Utility contact
Frequently asked questions about Waipahu-Ewa-Waianae
Is Waipahu-Ewa-Waianae tap water safe to drink?
EPA monitoring detected 22 contaminants in Waipahu-Ewa-Waianae's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Waipahu-Ewa-Waianae's water?
EPA monitoring detected Nitrate, Fluoride, Nitrate-Nitrite, TTHM, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Waipahu-Ewa-Waianae serve?
Waipahu-Ewa-Waianae reports serving 217,479 people in Hawaii, per its EPA record.
Has Waipahu-Ewa-Waianae had any water quality violations?
The EPA has 14 violations on file for Waipahu-Ewa-Waianae, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.