Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2012-07-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-09-30 |
| MCL | Health-based | Resolved | 2005-10-01 → 2005-10-31 |
| MCL | Health-based | Resolved | 2005-10-01 → 2005-10-31 |
| MCL | Health-based | Resolved | 2005-10-01 → 2005-10-31 |
| TT | Health-based | Resolved | 1997-12-17 → 1998-01-16 |
| TT | Health-based | Resolved | 1997-12-17 → 1998-01-16 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 18 µg/L No EPA limit set
worst single sample: 20.8 µg/L | 205/206 | SYR4 | 2012–2019 |
| Chloroform | 51.26 µg/L No EPA limit set
worst single sample: 70.2 µg/L | 205/206 | SYR4 | 2012–2019 |
| Dibromochloromethane | 5.48 µg/L No EPA limit set
worst single sample: 7.4 µg/L | 205/206 | SYR4 | 2012–2019 |
| Fluoride | 1200 µg/L 30% of the EPA limit 4000 µg/L
worst single sample: 1510 µg/L | 203/204 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 30.875 µg/L No EPA limit set
worst single sample: 43.8 µg/L | 196/196 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 21.825 µg/L No EPA limit set
worst single sample: 29 µg/L | 196/196 | SYR4 | 2012–2019 |
| TTHM | 75.315 µg/L 94% of the EPA limit 80 µg/L
worst single sample: 94.4 µg/L | 194/195 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 54.22 µg/L 90% of the EPA limit 60 µg/L
worst single sample: 71.1 µg/L | 193/194 | SYR4 | 2012–2019 |
| Copper | 330 µg/L 25% of the EPA limit 1300 µg/L
worst single sample: 780 µg/L | 86/88 | SYR4 | 2012–2017 |
| Dibromoacetic Acid | 1.52 µg/L No EPA limit set
worst single sample: 2 µg/L | 65/196 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 6.645 µg/L No EPA limit set
worst single sample: 13.4 µg/L | 52/196 | SYR4 | 2012–2019 |
| Nitrate | 3600 µg/L 36% of the EPA limit 10000 µg/L | 30/32 | SYR4 | 2012–2019 |
| Lead | 7.605 µg/L 51% of the EPA limit 15 µg/L
worst single sample: 8.7 µg/L | 24/89 | SYR4 | 2012–2017 |
| Nitrate-Nitrite | 3600 µg/L 36% of the EPA limit 10000 µg/L | 13/14 | SYR4 | 2012–2019 |
| Bromoform | 0.7500 µg/L No EPA limit set
worst single sample: 0.7800 µg/L | 11/206 | SYR4 | 2012–2019 |
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 10/10 | LCR | 2023 |
| Barium | 48.56 µg/L 2.4% of the EPA limit 2000 µg/L
worst single sample: 50.2 µg/L | 9/9 | SYR4 | 2012–2015 |
| Chromium | 2.92 µg/L 2.9% of the EPA limit 100 µg/L
worst single sample: 3.2 µg/L | 9/9 | SYR4 | 2012–2015 |
| Combined Radium (-226 And -228) | 0.4525 pCi/L 9% of the EPA limit 5 pCi/L
worst single sample: 0.4600 pCi/L | 4/4 | SYR4 | 2012–2013 |
| Gross Beta Particle Activity | 12.1 pCi/L No EPA limit set
worst single sample: 13 pCi/L | 4/4 | SYR4 | 2012–2013 |
| 2,4-D | 0.2082 µg/L 0.3% of the EPA limit 70 µg/L
worst single sample: 0.2130 µg/L | 3/23 | SYR4 | 2012–2017 |
| Atrazine | 0.1000 µg/L 3.3% of the EPA limit 3 µg/L | 3/10 | SYR4 | 2012–2017 |
| Dalapon | 0.1806 µg/L 0.1% of the EPA limit 200 µg/L
worst single sample: 0.1820 µg/L | 3/23 | SYR4 | 2012–2017 |
| Simazine | 0.0900 µg/L 2.3% of the EPA limit 4 µg/L | 3/10 | SYR4 | 2012–2017 |
| Arsenic | 0.5950 µg/L 5.9% of the EPA limit 10 µg/L
worst single sample: 0.6000 µg/L | 2/9 | SYR4 | 2012–2015 |
| Di(2-ethylhexyl) Adipate | 0.0880 µg/L 0% of the EPA limit 400 µg/L | 1/20 | SYR4 | 2012–2017 |
| Di(2-ethylhexyl) Phthalate | 0.6100 µg/L 10% of the EPA limit 6 µg/L | 1/20 | SYR4 | 2012–2017 |
| Monobromoacetic Acid | 1.24 µg/L No EPA limit set | 1/196 | SYR4 | 2012–2019 |
69 contaminants tested, none detected
Utility contact
Frequently asked questions about Veolia Water Delaware, Inc
Is Veolia Water Delaware, Inc tap water safe to drink?
EPA monitoring detected 37 contaminants in Veolia Water Delaware, Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Veolia Water Delaware, Inc's water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Fluoride, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Veolia Water Delaware, Inc serve?
Veolia Water Delaware, Inc reports serving 100,495 people in Delaware, per its EPA record.
Has Veolia Water Delaware, Inc had any water quality violations?
The EPA has 21 violations on file for Veolia Water Delaware, Inc, of which 11 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.