← Colorado

Tap water quality report

Rosewood Hills Property Hoa

EPA monitoring tested this supplier for 79 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
23
detected
135
people served
90
health-based violations
Water source
SWP
Ownership
Private
Counties served
Teller

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

90
health-based violations
129
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-10-01 → 2011-12-31
MCL Health-based Resolved 2011-10-01 → 2011-12-31
MCL Health-based Resolved 2011-10-01 → 2011-12-31
MCL Health-based Resolved 2011-10-01 → 2011-12-31
MCL Health-based Resolved 2011-10-01 → 2011-12-31
MCL Health-based Resolved 2011-07-01 → 2011-09-30
MCL Health-based Resolved 2011-07-01 → 2011-09-30
MCL Health-based Resolved 2011-07-01 → 2011-09-30
MCL Health-based Resolved 2011-07-01 → 2011-09-30
MCL Health-based Resolved 2011-04-01 → 2011-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3600 µg/L 36%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Lead
0.00050 mg/L 3.3%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Fluoride
3465 µg/L 87%
of the EPA limit 4000 µg/L
worst single sample: 3500 µg/L
8/8 SYR4 2012–2018
TTHM
20.905 µg/L 26%
of the EPA limit 80 µg/L
worst single sample: 29.2 µg/L
8/9 SYR4 2013–2019
Combined Radium (-226 And -228)
8.075 pCi/L 161%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 8.1 pCi/L
6/6 SYR4 2017–2019
Bromodichloromethane
1.7 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
5/7 SYR4 2015–2019
Dibromochloromethane
2.1 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
5/7 SYR4 2015–2019
Barium
148.5 µg/L 7.4%
of the EPA limit 2000 µg/L
worst single sample: 150 µg/L
4/4 SYR4 2012–2018
Bromoform
1.398 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
4/7 SYR4 2015–2019
Chloroform
23.4725 µg/L
No EPA limit set
worst single sample: 27.5 µg/L
4/7 SYR4 2015–2019
Total Haloacetic Acids (HAA5)
54.44 µg/L 91%
of the EPA limit 60 µg/L
worst single sample: 60 µg/L
3/7 SYR4 2013–2019
Beryllium, Total
0.7880 µg/L 20%
of the EPA limit 4 µg/L
worst single sample: 0.7900 µg/L
2/4 SYR4 2012–2018
Combined Uranium
4.855 µg/L 16%
of the EPA limit 30 µg/L
worst single sample: 4.9 µg/L
2/2 SYR4 2016–2019
Dibromoacetic Acid
1.295 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
2/5 SYR4 2015–2019
Gross Alpha, Excl. Radon And U
10.631 pCi/L 71%
of the EPA limit 15 pCi/L
worst single sample: 10.7 pCi/L
2/2 SYR4 2016–2019
Nitrate-Nitrite
3448 µg/L 34%
of the EPA limit 10000 µg/L
worst single sample: 3600 µg/L
2/2 SYR4 2013–2017
Selenium
0.8930 µg/L 1.8%
of the EPA limit 50 µg/L
worst single sample: 0.9100 µg/L
2/4 SYR4 2012–2018
Cadmium
0.1200 µg/L 2.4%
of the EPA limit 5 µg/L
1/4 SYR4 2012–2018
Dichloromethane
0.5900 µg/L 12%
of the EPA limit 5 µg/L
1/4 SYR4 2013–2018
Dalapon
2.1 µg/L 1.1%
of the EPA limit 200 µg/L
1/4 SYR4 2013–2018
Gross Beta Particle Activity
22 pCi/L
No EPA limit set
1/1 SYR4 2017
Monochloroacetic Acid
3.1 µg/L
No EPA limit set
1/5 SYR4 2015–2019
Nitrite
4.4 µg/L 0.4%
of the EPA limit 1000 µg/L
1/2 SYR4 2013–2017
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneChromiumDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SUTTON, CHRIS
Phone
719-687-0167
Email
[email protected]

Frequently asked questions about Rosewood Hills Property Hoa

Is Rosewood Hills Property Hoa tap water safe to drink?

EPA monitoring detected 23 contaminants in Rosewood Hills Property Hoa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Rosewood Hills Property Hoa's water?

EPA monitoring detected Nitrate, Lead, Fluoride, TTHM, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.

How many people does Rosewood Hills Property Hoa serve?

Rosewood Hills Property Hoa reports serving 135 people in Colorado, per its EPA record.

Has Rosewood Hills Property Hoa had any water quality violations?

The EPA has 129 violations on file for Rosewood Hills Property Hoa, of which 90 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.