← California

Tap water quality report

City of Daly City

EPA monitoring tested this supplier for 111 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
19
detected
104,901
people served
7
health-based violations
Water source
SWP
Ownership
Local government
Counties served
San Mateo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-12-01 → 2003-12-31
MCL Health-based Resolved 2003-12-01 → 2003-12-31
MCL Health-based Resolved 2000-05-01 → 2000-05-31
MCL Health-based Resolved 2000-05-01 → 2000-05-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
MCL Health-based Resolved 1998-07-01 → 1998-07-31
TT Health-based Resolved 1992-04-01 → 1993-08-10

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
16000 µg/L 160%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 38420 µg/L
1270/2036 SYR4 2012–2019
Chromium
18 µg/L 18%
of the EPA limit 100 µg/L
worst single sample: 25 µg/L
249/902 SYR4 2013–2019
Chloroform
57.9625 µg/L
No EPA limit set
worst single sample: 67.81 µg/L
232/232 SYR4 2012–2019
TTHM
59.7625 µg/L 75%
of the EPA limit 80 µg/L
worst single sample: 68.84 µg/L
232/232 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
54.725 µg/L 91%
of the EPA limit 60 µg/L
worst single sample: 63.8 µg/L
226/232 SYR4 2012–2019
Trichloroacetic Acid
24.735 µg/L
No EPA limit set
worst single sample: 30.2 µg/L
222/232 SYR4 2012–2019
Dichloroacetic Acid
32.08 µg/L
No EPA limit set
worst single sample: 42.6 µg/L
209/232 SYR4 2012–2019
Bromodichloromethane
4.4075 µg/L
No EPA limit set
worst single sample: 6.21 µg/L
202/232 SYR4 2012–2019
Dibromochloromethane
3 µg/L
No EPA limit set
worst single sample: 3.52 µg/L
93/232 SYR4 2012–2019
Bromoform
2.83 µg/L
No EPA limit set
worst single sample: 3.15 µg/L
41/232 SYR4 2012–2019
Dibromoacetic Acid
2.11 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
30/232 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
29/29 LCR 2025
Fluoride
168 µg/L 4.2%
of the EPA limit 4000 µg/L
worst single sample: 240 µg/L
19/55 SYR4 2012–2019
Monochloroacetic Acid
4 µg/L
No EPA limit set
13/232 SYR4 2012–2019
Monobromoacetic Acid
1 µg/L
No EPA limit set
3/232 SYR4 2012–2019
Arsenic
2.95 µg/L 30%
of the EPA limit 10 µg/L
worst single sample: 3 µg/L
2/17 SYR4 2013–2019
Lithium
13 µg/L
No EPA limit set
2/20 UCMR-5 2023
Diquat
2.2 µg/L 11%
of the EPA limit 20 µg/L
1/30 SYR4 2013–2019
Gross Beta Particle Activity
1.27 pCi/L
No EPA limit set
1/1 SYR4 2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
COSGROVE, JOSHUA
Phone
650-991-8206
Email
[email protected]

Frequently asked questions about City of Daly City

Is City of Daly City tap water safe to drink?

EPA monitoring detected 19 contaminants in City of Daly City's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Daly City's water?

EPA monitoring detected Nitrate, Chromium, Chloroform, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does City of Daly City serve?

City of Daly City reports serving 104,901 people in California, per its EPA record.

Has City of Daly City had any water quality violations?

The EPA has 7 violations on file for City of Daly City, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.