← California

Tap water quality report

Coachella Vwd: Cove Community

EPA monitoring tested this supplier for 112 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

112
contaminants tested
24
detected
270,000
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Riverside

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
1
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Archived 1989-10-01 → 1989-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
8588 µg/L 86%
of the EPA limit 10000 µg/L
worst single sample: 12656 µg/L
2260/2352 SYR4 2012–2019
Arsenic
21 µg/L 210%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 32 µg/L
851/1438 SYR4 2012–2019
Chromium
18 µg/L 18%
of the EPA limit 100 µg/L
worst single sample: 33 µg/L
327/619 SYR4 2012–2019
Fluoride
918 µg/L 23%
of the EPA limit 4000 µg/L
worst single sample: 1500 µg/L
252/252 SYR4 2012–2019
Nitrate-Nitrite
973000 µg/L 9730%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 1000000 µg/L
179/193 SYR4 2012–2019
TTHM
17.55 µg/L 22%
of the EPA limit 80 µg/L
worst single sample: 22 µg/L
150/178 SYR4 2012–2019
Bromoform
8.93 µg/L
No EPA limit set
worst single sample: 15 µg/L
128/179 SYR4 2012–2019
Dibromochloromethane
5.28 µg/L
No EPA limit set
worst single sample: 6.7 µg/L
125/179 SYR4 2012–2019
Bromodichloromethane
4.36 µg/L
No EPA limit set
worst single sample: 5.5 µg/L
89/164 SYR4 2012–2019
Combined Uranium
18.543 µg/L 62%
of the EPA limit 30 µg/L
worst single sample: 21.605 µg/L
54/55 SYR4 2012–2019
Chloroform
4.13 µg/L
No EPA limit set
worst single sample: 4.6 µg/L
38/144 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
35/35 LCR 2024
Barium
78.4 µg/L 3.9%
of the EPA limit 2000 µg/L
worst single sample: 140 µg/L
33/245 SYR4 2012–2019
Dibromoacetic Acid
2.29 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
28/131 SYR4 2012–2019
1,2-DIBROMO-3-CHLOROPROPANE
0.0643 µg/L 32%
of the EPA limit 0.2000 µg/L
worst single sample: 0.0670 µg/L
24/69 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.25 µg/L 10%
of the EPA limit 60 µg/L
worst single sample: 6.6 µg/L
11/116 SYR4 2012–2019
Monochloroacetic Acid
6.355 µg/L
No EPA limit set
worst single sample: 6.6 µg/L
8/114 SYR4 2012–2019
Tetrachloroethylene
0.8400 µg/L 17%
of the EPA limit 5 µg/L
7/266 SYR4 2012–2019
Dichloroacetic Acid
1.475 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
6/112 SYR4 2012–2019
Copper
556 µg/L 43%
of the EPA limit 1300 µg/L
worst single sample: 560 µg/L
5/245 SYR4 2012–2019
Lithium
17.7 µg/L
No EPA limit set
4/40 UCMR-5 2025
Selenium
5.74 µg/L 11%
of the EPA limit 50 µg/L
worst single sample: 5.8 µg/L
3/288 SYR4 2012–2019
Gross Beta Particle Activity
4.58 pCi/L
No EPA limit set
1/1 SYR4 2017
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
1/112 SYR4 2012–2019
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BARRETT, JAMES
Phone
760-398-2651
Email
[email protected]

Frequently asked questions about Coachella Vwd: Cove Community

Is Coachella Vwd: Cove Community tap water safe to drink?

EPA monitoring detected 24 contaminants in Coachella Vwd: Cove Community's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Coachella Vwd: Cove Community's water?

EPA monitoring detected Nitrate, Arsenic, Chromium, Fluoride, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Coachella Vwd: Cove Community serve?

Coachella Vwd: Cove Community reports serving 270,000 people in California, per its EPA record.

Has Coachella Vwd: Cove Community had any water quality violations?

The EPA has 1 violation on file for Coachella Vwd: Cove Community, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.