← California

Tap water quality report

Santa Monica-City, Water Division

EPA monitoring tested this supplier for 110 contaminants and detected 37. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
37
detected
89,947
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Los Angeles

Compliance record

No violations on file. The EPA has no formal drinking-water violations recorded for this supplier.

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0088 µg/L 1/8 2024
PFBS 0.0045 µg/L 1/8 2024
Pfhpa 0.0050 µg/L 1/8 2024
Pfhxa 0.0179 µg/L 1/8 2024
PFOA 0.0046 µg/L 1/8 2024
Pfpea 0.0220 µg/L 1/8 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Trichloroethylene
20.03 µg/L 401%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 63.2 µg/L
2238/7209 SYR4 2012–2019
Bromoform
7.5 µg/L
No EPA limit set
worst single sample: 35.4 µg/L
1823/6622 SYR4 2012–2019
1,1-Dichloroethylene
4.2 µg/L 60%
of the EPA limit 7 µg/L
worst single sample: 12.6 µg/L
1607/7209 SYR4 2012–2019
Dibromochloromethane
4.9 µg/L
No EPA limit set
worst single sample: 19 µg/L
1481/6879 SYR4 2012–2019
Tetrachloroethylene
17.54 µg/L 351%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 43.4 µg/L
894/7208 SYR4 2012–2019
Chloroform
2.8 µg/L
No EPA limit set
worst single sample: 18 µg/L
773/6756 SYR4 2012–2019
Nitrate
6329.13 µg/L 63%
of the EPA limit 10000 µg/L
worst single sample: 7400 µg/L
640/652 SYR4 2012–2019
cis-1,2-Dichloroethylene
2.575 µg/L 3.7%
of the EPA limit 70 µg/L
worst single sample: 6.4 µg/L
526/7209 SYR4 2012–2019
TTHM
33.715 µg/L 42%
of the EPA limit 80 µg/L
worst single sample: 55 µg/L
400/1071 SYR4 2012–2019
Bromodichloromethane
7.235 µg/L
No EPA limit set
worst single sample: 16 µg/L
252/6895 SYR4 2012–2019
Combined Uranium
41.869 µg/L 140%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 47.68 µg/L
139/180 SYR4 2012–2019
Dibromoacetic Acid
4.5 µg/L
No EPA limit set
worst single sample: 5.4 µg/L
119/192 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
14.5 µg/L 24%
of the EPA limit 60 µg/L
worst single sample: 20 µg/L
86/192 SYR4 2012–2019
Fluoride
360 µg/L 9%
of the EPA limit 4000 µg/L
worst single sample: 390 µg/L
52/52 SYR4 2012–2019
Dichloroacetic Acid
7.05 µg/L
No EPA limit set
worst single sample: 9.8 µg/L
51/192 SYR4 2012–2019
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
36/36 LCR 2025
Trichloroacetic Acid
4.9 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
34/192 SYR4 2012–2019
Barium
90.12 µg/L 4.5%
of the EPA limit 2000 µg/L
worst single sample: 117 µg/L
29/29 SYR4 2012–2018
Arsenic
1.3 µg/L 13%
of the EPA limit 10 µg/L
worst single sample: 1.4 µg/L
22/29 SYR4 2012–2018
Nitrate-Nitrite
502000 µg/L 5020%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 570000 µg/L
18/19 SYR4 2015–2018
Toluene
3.04 µg/L 0.3%
of the EPA limit 1000 µg/L
worst single sample: 3.4 µg/L
13/7132 SYR4 2012–2019
Selenium
12.42 µg/L 25%
of the EPA limit 50 µg/L
worst single sample: 16.9 µg/L
8/30 SYR4 2012–2018
Monochloroacetic Acid
13.8 µg/L
No EPA limit set
worst single sample: 15 µg/L
7/192 SYR4 2012–2019
Carbon Tetrachloride
0.5000 µg/L 10%
of the EPA limit 5 µg/L
6/7209 SYR4 2012–2019
Chromium
2.95 µg/L 3%
of the EPA limit 100 µg/L
worst single sample: 3.1 µg/L
6/30 SYR4 2012–2018
Lithium
34.8 µg/L
No EPA limit set
6/8 UCMR-5 2024
Copper
45.58 µg/L 3.5%
of the EPA limit 1300 µg/L
worst single sample: 49 µg/L
4/29 SYR4 2012–2018
Monobromoacetic Acid
2.44 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
4/192 SYR4 2012–2019
Lead
1.485 µg/L 9.9%
of the EPA limit 15 µg/L
worst single sample: 1.5 µg/L
2/29 SYR4 2012–2018
Cadmium
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/29 SYR4 2012–2018
Gross Beta Particle Activity
4.6 pCi/L
No EPA limit set
1/4 SYR4 2013–2017
73 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCarbofuranChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpsPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneVinyl ChlorideXylenes, TotalO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JENSEN, ERIC
Phone
424-508-2876
Email
[email protected]

Frequently asked questions about Santa Monica-City, Water Division

Is Santa Monica-City, Water Division tap water safe to drink?

EPA monitoring detected 37 contaminants in Santa Monica-City, Water Division's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Santa Monica-City, Water Division's water?

EPA monitoring detected Trichloroethylene, Bromoform, 1,1-Dichloroethylene, Dibromochloromethane, Tetrachloroethylene, and others. The full list with the level and data source for each is above.

How many people does Santa Monica-City, Water Division serve?

Santa Monica-City, Water Division reports serving 89,947 people in California, per its EPA record.

Has Santa Monica-City, Water Division had any water quality violations?

The EPA has no formal drinking-water violations on file for Santa Monica-City, Water Division.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.