← California

Tap water quality report

City of Pleasanton

EPA monitoring tested this supplier for 111 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
26
detected
76,689
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Alameda

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
4
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1995-12-01 → 1996-01-31
MCL Health-based Resolved 1995-12-01 → 1996-01-31
MCL Health-based Resolved 1995-11-01 → 1995-11-30
MCL Health-based Resolved 1995-11-01 → 1995-11-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFHXS 0.0220 µg/L 5/8 2025
PFOS 0.0260 µg/L 5/8 2025
PFBS 0.0061 µg/L 4/8 2025
Pfhxa 0.0041 µg/L 4/8 2025
PFOA 0.0051 µg/L 4/8 2025
Pfba 0.0063 µg/L 3/8 2025
Pfpea 0.0041 µg/L 2/8 2025
Pfpes 0.0043 µg/L 1/8 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4972 µg/L 50%
of the EPA limit 10000 µg/L
worst single sample: 5650 µg/L
100/100 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
32/32 LCR 2025
Fluoride
160 µg/L 4%
of the EPA limit 4000 µg/L
worst single sample: 210 µg/L
21/26 SYR4 2012–2018
TTHM
45.34 µg/L 57%
of the EPA limit 80 µg/L
worst single sample: 58.45 µg/L
21/24 SYR4 2019
Total Haloacetic Acids (HAA5)
22.4 µg/L 37%
of the EPA limit 60 µg/L
worst single sample: 26.6 µg/L
21/24 SYR4 2019
Bromodichloromethane
7.004 µg/L
No EPA limit set
worst single sample: 8.98 µg/L
20/24 SYR4 2019
Chloroform
19.7325 µg/L
No EPA limit set
worst single sample: 20.73 µg/L
20/24 SYR4 2019
Dichloroacetic Acid
11.925 µg/L
No EPA limit set
worst single sample: 12.4 µg/L
20/24 SYR4 2019
Dibromochloromethane
17.832 µg/L
No EPA limit set
worst single sample: 23.7 µg/L
19/24 SYR4 2019
Trichloroacetic Acid
11.4 µg/L
No EPA limit set
worst single sample: 12.3 µg/L
19/24 SYR4 2019
Dibromoacetic Acid
10.255 µg/L
No EPA limit set
worst single sample: 13.7 µg/L
14/24 SYR4 2019
Barium
326 µg/L 16%
of the EPA limit 2000 µg/L
worst single sample: 330 µg/L
9/9 SYR4 2012–2018
Bromoform
22.318 µg/L
No EPA limit set
worst single sample: 23.26 µg/L
7/24 SYR4 2019
Lithium
16.8 µg/L
No EPA limit set
3/8 UCMR-5 2025
Monobromoacetic Acid
1.99 µg/L
No EPA limit set
worst single sample: 2 µg/L
2/24 SYR4 2019
Combined Uranium
2.831 µg/L 9.4%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Glyphosate
50 µg/L 7.1%
of the EPA limit 700 µg/L
1/14 SYR4 2014–2018
Gross Beta Particle Activity
0.5290 pCi/L
No EPA limit set
1/1 SYR4 2018
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpaPfhpsPfmbaPfmpaPFNAPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
COX, JEREMY, J
Phone
925-931-5522
Email
[email protected]

Frequently asked questions about City of Pleasanton

Is City of Pleasanton tap water safe to drink?

EPA monitoring detected 26 contaminants in City of Pleasanton's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Pleasanton's water?

EPA monitoring detected Nitrate, Lead, Fluoride, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does City of Pleasanton serve?

City of Pleasanton reports serving 76,689 people in California, per its EPA record.

Has City of Pleasanton had any water quality violations?

The EPA has 4 violations on file for City of Pleasanton, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.