← Arkansas

Tap water quality report

Sevier Co Water Association

EPA monitoring tested this supplier for 109 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
17
detected
5,365
people served
56
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Polk, Sevier

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

56
health-based violations
58
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2012-07-01 → 2012-09-30
MCL Health-based Resolved 2012-07-01 → 2012-09-30
MCL Health-based Resolved 2012-07-01 → 2012-09-30
MCL Health-based Resolved 2012-04-01 → 2012-06-30
MCL Health-based Resolved 2012-04-01 → 2012-06-30
MCL Health-based Resolved 2012-04-01 → 2012-06-30
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
8.19 µg/L
No EPA limit set
worst single sample: 8.8 µg/L
83/83 SYR4 2012–2019
Chloroform
95.52 µg/L
No EPA limit set
worst single sample: 108 µg/L
83/83 SYR4 2012–2019
Dichloroacetic Acid
26.875 µg/L
No EPA limit set
worst single sample: 32.3 µg/L
66/66 SYR4 2012–2019
TTHM
104 µg/L 130%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 118 µg/L
66/66 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
43.975 µg/L 73%
of the EPA limit 60 µg/L
worst single sample: 50.8 µg/L
66/66 SYR4 2012–2019
Trichloroacetic Acid
16.36 µg/L
No EPA limit set
worst single sample: 20.6 µg/L
65/66 SYR4 2012–2019
Copper
361.5 µg/L 28%
of the EPA limit 1300 µg/L
worst single sample: 850 µg/L
58/160 SYR4 2012–2017
Lead
13.5 µg/L 90%
of the EPA limit 15 µg/L
worst single sample: 18 µg/L
51/170 SYR4 2012–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Dibromochloromethane
1.2 µg/L
No EPA limit set
17/88 SYR4 2012–2019
Monochloroacetic Acid
3.425 µg/L
No EPA limit set
worst single sample: 3.7 µg/L
12/66 SYR4 2012–2019
Nitrate-Nitrite
583.5 µg/L 5.8%
of the EPA limit 10000 µg/L
worst single sample: 710 µg/L
12/12 SYR4 2012–2019
Nitrate
360 µg/L 3.6%
of the EPA limit 10000 µg/L
6/6 SYR4 2012–2017
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
2/66 SYR4 2012–2019
Gross Beta Particle Activity
2.7 pCi/L
No EPA limit set
1/11 SYR4 2012–2019
Hexachlorocyclopentadiene
0.0200 µg/L 0%
of the EPA limit 50 µg/L
1/6 SYR4 2014–2018
Monobromoacetic Acid
1.1 µg/L
No EPA limit set
1/66 SYR4 2012–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MARTZ, BRIAN
Phone
870-642-5289
Email
[email protected]

Frequently asked questions about Sevier Co Water Association

Is Sevier Co Water Association tap water safe to drink?

EPA monitoring detected 17 contaminants in Sevier Co Water Association's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sevier Co Water Association's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Sevier Co Water Association serve?

Sevier Co Water Association reports serving 5,365 people in Arkansas, per its EPA record.

Has Sevier Co Water Association had any water quality violations?

The EPA has 58 violations on file for Sevier Co Water Association, of which 56 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.