Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2013-10-01 → 2013-12-31 |
| MCL | Health-based | Resolved | 2013-10-01 → 2013-12-31 |
| MCL | Health-based | Resolved | 2013-10-01 → 2013-12-31 |
| MCL | Health-based | Resolved | 2013-10-01 → 2013-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-10-01 → 2012-12-31 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chlorite | 682.75 µg/L 68% of the EPA limit 1000 µg/L
worst single sample: 1650 µg/L | 146/201 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.62 µg/L No EPA limit set
worst single sample: 12.5 µg/L | 85/85 | SYR4 | 2012–2019 |
| Chloroform | 80.08 µg/L No EPA limit set
worst single sample: 96.2 µg/L | 85/85 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 24.62 µg/L No EPA limit set
worst single sample: 33.2 µg/L | 65/65 | SYR4 | 2012–2019 |
| TTHM | 92.58 µg/L 116% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 109 µg/L | 65/65 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 42.56 µg/L 71% of the EPA limit 60 µg/L
worst single sample: 75.5 µg/L | 65/65 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 18.39 µg/L No EPA limit set
worst single sample: 40.3 µg/L | 62/65 | SYR4 | 2012–2019 |
| Fluoride | 970.5 µg/L 24% of the EPA limit 4000 µg/L
worst single sample: 1030 µg/L | 60/63 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.17 µg/L No EPA limit set
worst single sample: 2.6 µg/L | 54/92 | SYR4 | 2012–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Monochloroacetic Acid | 4.11 µg/L No EPA limit set
worst single sample: 4.5 µg/L | 14/65 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 340 µg/L 3.4% of the EPA limit 10000 µg/L | 14/18 | SYR4 | 2012–2019 |
| Copper | 121.5 µg/L 9.3% of the EPA limit 1300 µg/L
worst single sample: 130 µg/L | 11/60 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 3.675 pCi/L No EPA limit set
worst single sample: 3.7 pCi/L | 6/11 | SYR4 | 2012–2019 |
| Lead | 1.85 µg/L 12% of the EPA limit 15 µg/L
worst single sample: 2 µg/L | 4/69 | SYR4 | 2012–2019 |
| Barium | 230 µg/L 12% of the EPA limit 2000 µg/L | 1/14 | SYR4 | 2012–2019 |
| Chromium | 1 µg/L 1% of the EPA limit 100 µg/L | 1/9 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.1 µg/L No EPA limit set | 1/65 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.5 µg/L No EPA limit set | 1/65 | SYR4 | 2012–2019 |
89 contaminants tested, none detected
Utility contact
Frequently asked questions about Greenwood Waterworks
Is Greenwood Waterworks tap water safe to drink?
EPA monitoring detected 19 contaminants in Greenwood Waterworks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Greenwood Waterworks's water?
EPA monitoring detected Chlorite, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.
How many people does Greenwood Waterworks serve?
Greenwood Waterworks reports serving 9,905 people in Arkansas, per its EPA record.
Has Greenwood Waterworks had any water quality violations?
The EPA has 347 violations on file for Greenwood Waterworks, of which 196 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.