← Arkansas

Tap water quality report

Benton Waterworks

EPA monitoring tested this supplier for 107 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
16
detected
30,681
people served
9
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Saline

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
9
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2006-01-01 → 2006-03-31
TT Health-based Resolved 2006-01-01 → 2006-03-31
TT Health-based Resolved 2002-10-01 → 2002-12-31
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1997-07-01 → 1997-07-31
MCL Health-based Archived 1994-05-01 → 1994-05-31
MCL Health-based Archived 1994-05-01 → 1994-05-31
MCL Health-based Archived 1994-05-01 → 1994-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
940 µg/L 24%
of the EPA limit 4000 µg/L
worst single sample: 1060 µg/L
200/200 SYR4 2012–2019
Bromodichloromethane
13.55 µg/L
No EPA limit set
worst single sample: 15.8 µg/L
111/111 SYR4 2012–2019
Chloroform
49.35 µg/L
No EPA limit set
worst single sample: 66.8 µg/L
111/111 SYR4 2012–2019
Dichloroacetic Acid
13.84 µg/L
No EPA limit set
worst single sample: 17.5 µg/L
107/107 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
28.27 µg/L 47%
of the EPA limit 60 µg/L
worst single sample: 39.7 µg/L
107/107 SYR4 2012–2019
Trichloroacetic Acid
11.54 µg/L
No EPA limit set
worst single sample: 17.9 µg/L
107/107 SYR4 2012–2019
Dibromochloromethane
4.075 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
106/117 SYR4 2012–2019
TTHM
67.6 µg/L 85%
of the EPA limit 80 µg/L
worst single sample: 82.4 µg/L
103/103 SYR4 2012–2019
Copper
217 µg/L 17%
of the EPA limit 1300 µg/L
worst single sample: 448 µg/L
51/90 SYR4 2013–2019
Monochloroacetic Acid
5.9 µg/L
No EPA limit set
worst single sample: 6.4 µg/L
21/107 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Lead
11.25 µg/L 75%
of the EPA limit 15 µg/L
worst single sample: 12 µg/L
16/99 SYR4 2012–2019
Dibromoacetic Acid
1.17 µg/L
No EPA limit set
worst single sample: 1.2 µg/L
7/107 SYR4 2012–2019
Nitrate-Nitrite
340 µg/L 3.4%
of the EPA limit 10000 µg/L
4/18 SYR4 2012–2019
Monobromoacetic Acid
1.57 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
3/107 SYR4 2012–2019
Gross Beta Particle Activity
2.8 pCi/L
No EPA limit set
1/11 SYR4 2012–2019
91 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DEJARNATT, JON
Phone
501-776-5942
Email
[email protected]

Frequently asked questions about Benton Waterworks

Is Benton Waterworks tap water safe to drink?

EPA monitoring detected 16 contaminants in Benton Waterworks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Benton Waterworks's water?

EPA monitoring detected Fluoride, Bromodichloromethane, Chloroform, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Benton Waterworks serve?

Benton Waterworks reports serving 30,681 people in Arkansas, per its EPA record.

Has Benton Waterworks had any water quality violations?

The EPA has 9 violations on file for Benton Waterworks, of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.