← Arkansas

Tap water quality report

Paris Waterworks

EPA monitoring tested this supplier for 109 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
14
detected
4,935
people served
51
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Logan

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

51
health-based violations
69
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
TT Health-based Resolved 2022-02-01 → 2022-02-28
TT Health-based Resolved 2022-02-01 → 2022-02-28
TT Health-based Resolved 2022-02-01 → 2022-02-28
TT Health-based Resolved 2022-02-01 → 2022-02-28
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
1068 µg/L 27%
of the EPA limit 4000 µg/L
worst single sample: 1230 µg/L
85/91 SYR4 2012–2019
Bromodichloromethane
9.8 µg/L
No EPA limit set
worst single sample: 12.1 µg/L
65/65 SYR4 2012–2019
Chloroform
79.58 µg/L
No EPA limit set
worst single sample: 93.3 µg/L
65/65 SYR4 2012–2019
Dichloroacetic Acid
35.17 µg/L
No EPA limit set
worst single sample: 43.1 µg/L
58/58 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
75.515 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 83.9 µg/L
58/58 SYR4 2012–2019
Trichloroacetic Acid
36 µg/L
No EPA limit set
worst single sample: 41 µg/L
58/58 SYR4 2012–2019
TTHM
90.925 µg/L 114%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 107 µg/L
56/56 SYR4 2012–2019
Monochloroacetic Acid
4.9 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
34/58 SYR4 2012–2019
Copper
61.5 µg/L 4.7%
of the EPA limit 1300 µg/L
worst single sample: 62.1 µg/L
21/60 SYR4 2013–2019
Dibromochloromethane
1.6 µg/L
No EPA limit set
21/71 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Lead
11 µg/L 73%
of the EPA limit 15 µg/L
worst single sample: 18 µg/L
11/69 SYR4 2012–2019
Nitrate-Nitrite
227 µg/L 2.3%
of the EPA limit 10000 µg/L
worst single sample: 240 µg/L
3/9 SYR4 2012–2019
Gross Beta Particle Activity
3 pCi/L
No EPA limit set
1/9 SYR4 2012–2019
95 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitrateNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROGERS, DANIEL
Phone
479-963-1715
Email
[email protected]

Frequently asked questions about Paris Waterworks

Is Paris Waterworks tap water safe to drink?

EPA monitoring detected 14 contaminants in Paris Waterworks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Paris Waterworks's water?

EPA monitoring detected Fluoride, Bromodichloromethane, Chloroform, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Paris Waterworks serve?

Paris Waterworks reports serving 4,935 people in Arkansas, per its EPA record.

Has Paris Waterworks had any water quality violations?

The EPA has 69 violations on file for Paris Waterworks, of which 51 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.