Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MR | Monitoring | Unaddressed | 2022-01-01 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2005-01-01 → 2007-12-31 |
| MR | Monitoring | Resolved | 2004-01-01 → 2007-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 1640 µg/L 16% of the EPA limit 10000 µg/L
worst single sample: 1680 µg/L | 26/26 | SYR4 | 2012–2019 |
| Lead | 0.00083 mg/L 5.5% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2024 |
| Copper | 151.35 µg/L 12% of the EPA limit 1300 µg/L
worst single sample: 165 µg/L | 14/16 | SYR4 | 2013–2018 |
| TTHM | 10.635 µg/L 13% of the EPA limit 80 µg/L
worst single sample: 22.4 µg/L | 14/16 | SYR4 | 2012–2019 |
| Lead | 4.2 µg/L 28% of the EPA limit 15 µg/L | 12/16 | SYR4 | 2013–2018 |
| Nitrate-Nitrite | 1571.5 µg/L 16% of the EPA limit 10000 µg/L
worst single sample: 1680 µg/L | 8/8 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 2.068 µg/L 3.4% of the EPA limit 60 µg/L
worst single sample: 2.35 µg/L | 7/16 | SYR4 | 2012–2019 |
| Barium | 40.025 µg/L 2% of the EPA limit 2000 µg/L
worst single sample: 42 µg/L | 6/6 | SYR4 | 2013–2018 |
| Chloroform | 1.245 µg/L No EPA limit set
worst single sample: 1.36 µg/L | 6/15 | SYR4 | 2013–2019 |
| Fluoride | 171 µg/L 4.3% of the EPA limit 4000 µg/L
worst single sample: 175 µg/L | 5/5 | SYR4 | 2013–2018 |
| Bromodichloromethane | 0.7715 µg/L No EPA limit set
worst single sample: 0.8000 µg/L | 4/15 | SYR4 | 2013–2019 |
| Dibromochloromethane | 0.4880 µg/L No EPA limit set
worst single sample: 0.5000 µg/L | 3/15 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 3.545 pCi/L 24% of the EPA limit 15 pCi/L
worst single sample: 3.6 pCi/L | 2/6 | SYR4 | 2015–2016 |
| Antimony, Total | 0.6600 µg/L 11% of the EPA limit 6 µg/L | 1/6 | SYR4 | 2013–2018 |
| Combined Radium (-226 And -228) | 0.8000 pCi/L 16% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2015 |
| Ethylbenzene | 0.3000 µg/L 0% of the EPA limit 700 µg/L | 1/15 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 3.5 pCi/L No EPA limit set | 1/1 | SYR4 | 2015 |
| Selenium | 0.9700 µg/L 1.9% of the EPA limit 50 µg/L | 1/6 | SYR4 | 2013–2018 |
| Styrene | 0.2200 µg/L 0.2% of the EPA limit 100 µg/L | 1/15 | SYR4 | 2013–2019 |
| Toluene | 0.2500 µg/L 0% of the EPA limit 1000 µg/L | 1/15 | SYR4 | 2013–2019 |
| Xylenes, Total | 0.5700 µg/L 0% of the EPA limit 10000 µg/L | 1/13 | SYR4 | 2013–2019 |
85 contaminants tested, none detected
Utility contact
Frequently asked questions about Central Talladega County Water District
Is Central Talladega County Water District tap water safe to drink?
EPA monitoring detected 21 contaminants in Central Talladega County Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Central Talladega County Water District's water?
EPA monitoring detected Nitrate, Lead, Copper, TTHM, Lead, and others. The full list with the level and data source for each is above.
How many people does Central Talladega County Water District serve?
Central Talladega County Water District reports serving 3,600 people in Alabama, per its EPA record.
Has Central Talladega County Water District had any water quality violations?
The EPA has 16 violations on file for Central Talladega County Water District, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.