What was found in Hanover's water
The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Fluoride | 868.5 µg/L 22% of the EPA limit 4000 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Copper | 102 µg/L 7.8% of the EPA limit 1300 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019
Highest in the city: 435.2 µg/L — OAK HILL ESTATES · 350 people · 2018 | 5/5 | SYR4 |
| Nitrate-Nitrite | 270 µg/L 2.7% of the EPA limit 10000 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 3/5 | SYR4 |
| TTHM | 74 µg/L 93% of the EPA limit 80 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Chloroform | 67.25 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Barium | 58.8 µg/L 2.9% of the EPA limit 2000 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 4/5 | SYR4 |
| Total Haloacetic Acids (HAA5) | 56 µg/L 93% of the EPA limit 60 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Dichloroacetic Acid | 31 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Trichloroacetic Acid | 29 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 3/5 | SYR4 |
| Lead | 8.4 µg/L 56% of the EPA limit 15 µg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019
Highest in the city: 26.2 µg/L — GEORGETOWN SUBDIVISION · 120 people · 2018 | 5/5 | SYR4 |
| Gross Alpha, Excl. Radon And U | 17.03 pCi/L 114% of the EPA limit, at the 95th percentile of samples — 15 pCi/L Highest in the city: DIANNE RIDGE · 59 people · 2018 | 1/5 | SYR4 |
| Gross Beta Particle Activity | 7.6 pCi/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2014
Highest in the city: 13.25 pCi/L — DIANNE RIDGE · 59 people · 2019 | 5/5 | SYR4 |
| Bromodichloromethane | 10 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Xylenes, Total | 5.5 µg/L 0.1% of the EPA limit 10000 µg/L Highest in the city: DIANNE RIDGE · 59 people · 2019 | 1/5 | SYR4 |
| Dibromoacetic Acid | 2.865 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 1/5 | SYR4 |
| Monochloroacetic Acid | 2.495 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 1/5 | SYR4 |
| Dibromochloromethane | 2.3 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 5/5 | SYR4 |
| Combined Radium (-226 And -228) | 0.4000 pCi/L 8% of the EPA limit 5 pCi/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2014
Highest in the city: 2 pCi/L — GEORGETOWN SUBDIVISION · 120 people · 2018 | 5/5 | SYR4 |
| Combined Uranium | 1.788 µg/L 6% of the EPA limit 30 µg/L Highest in the city: DIANNE RIDGE · 59 people · 2018 | 1/5 | SYR4 |
| Ethylbenzene | 1.08 µg/L 0.2% of the EPA limit 700 µg/L Highest in the city: DIANNE RIDGE · 59 people · 2019 | 1/5 | SYR4 |
| Toluene | 0.8850 µg/L 0.1% of the EPA limit 1000 µg/L Highest in the city: DIANNE RIDGE · 59 people · 2019 | 1/5 | SYR4 |
| Bromoform | 0.6000 µg/L No EPA limit set Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2019 | 1/5 | SYR4 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L Main supplier: HANOVER SUBURBAN WATER SYSTEM · 57,931 people · 2025
Highest in the city: 0.0050 mg/L — OAK HILL ESTATES · 350 people · 2024 | 5/5 | LCR |
Water suppliers serving Hanover
| Supplier | Population served |
|---|---|
| HANOVER SUBURBAN WATER SYSTEM | 57,931 |
| OAK HILL ESTATES | 350 |
| SINCLAIR MANOR | 155 |
| GEORGETOWN SUBDIVISION | 120 |
| DIANNE RIDGE | 59 |
Frequently asked questions about Hanover tap water
Is Hanover tap water safe to drink?
EPA testing detected 23 contaminants in the water serving Hanover. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.
How many water suppliers serve Hanover?
5 public water suppliers report drinking-water monitoring for Hanover, Virginia to the EPA. Each is listed above with its population served.
What contaminants are in Hanover's water?
The contaminants EPA monitoring detected in Hanover include Fluoride, Copper, Nitrate-Nitrite, TTHM, Chloroform. The full list, with the level at the main supplier and the data source, is in the table above.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.