← Pennsylvania

Tap water quality report

Bellefonte, PA

EPA monitoring detected 27 contaminants across the 7 water suppliers serving Bellefonte. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

7
water suppliers
16,654
people served
27
contaminants found

What was found in Bellefonte's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2139 µg/L 21%
of the EPA limit 10000 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 8630 µg/L — SBWJA GROVE PARK · 185 people · 2019
5/7 SYR4
Copper
125 µg/L 9.6%
of the EPA limit 1300 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 965.45 µg/L — SBWJA HAMPTON HILLS OPEQUON · 684 people · 2019
7/7 SYR4
Barium
29.5 µg/L 1.5%
of the EPA limit 2000 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 557 µg/L — EAGLE CREEK · 60 people · 2018
7/7 SYR4
Fluoride
277 µg/L 6.9%
of the EPA limit 4000 µg/L
Highest in the city: EAGLE CREEK · 60 people · 2018
1/7 SYR4
TTHM
5.188 µg/L 6.5%
of the EPA limit 80 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 41.235 µg/L — STATE CORR INST BENNER TWP · 2,850 people · 2019
6/7 SYR4
Total Haloacetic Acids (HAA5)
37.24 µg/L 62%
of the EPA limit 60 µg/L
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
3/7 SYR4
Chloroform
31.875 µg/L
No EPA limit set
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
5/7 SYR4
Trichloroacetic Acid
21.185 µg/L
No EPA limit set
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
2/7 SYR4
Nitrite
21 µg/L 2.1%
of the EPA limit 1000 µg/L
Highest in the city: EAGLE CREEK · 60 people · 2019
1/7 SYR4
Dichloroacetic Acid
16.885 µg/L
No EPA limit set
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
2/7 SYR4
Bromoform
1.53 µg/L
No EPA limit set
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 15.6 µg/L — EAGLE CREEK · 60 people · 2019
4/7 SYR4
Lead
10.179 µg/L 68%
of the EPA limit 15 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 13.25 µg/L — EAGLE CREEK · 60 people · 2019
7/7 SYR4
Dibromochloromethane
2.265 µg/L
No EPA limit set
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 9.9 µg/L — EAGLE CREEK · 60 people · 2019
6/7 SYR4
Bromodichloromethane
1.558 µg/L
No EPA limit set
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 9.405 µg/L — STATE CORR INST BENNER TWP · 2,850 people · 2019
6/7 SYR4
Selenium
4.06 µg/L 8.1%
of the EPA limit 50 µg/L
Highest in the city: SBWJA HAMPTON HILLS OPEQUON · 684 people · 2018
2/7 SYR4
Chromium
3.36 µg/L 3.4%
of the EPA limit 100 µg/L
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
1/7 SYR4
Dibromoacetic Acid
3 µg/L
No EPA limit set
Highest in the city: EAGLE CREEK · 60 people · 2019
3/7 SYR4
Di(2-ethylhexyl) Phthalate
1.47 µg/L 25%
of the EPA limit 6 µg/L
Highest in the city: SPRING TWP WATER AUTHORITY · 3,300 people · 2019
2/7 SYR4
Tetrachloroethylene
1.438 µg/L 29%
of the EPA limit 5 µg/L
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
1/7 SYR4
Beryllium, Total
1 µg/L 25%
of the EPA limit 4 µg/L
Highest in the city: EMPIRE MOBILE HOME PARK · 75 people · 2018
1/7 SYR4
Trichloroethylene
0.5200 µg/L 10%
of the EPA limit 5 µg/L
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2019
1/7 SYR4
Endrin
0.2400 µg/L 12%
of the EPA limit 2 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
1/7 SYR4
Atrazine
0.0331 µg/L 1.1%
of the EPA limit 3 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 0.2000 µg/L — SBWJA GROVE PARK · 185 people · 2019
4/7 SYR4
Chlordane
0.0185 µg/L 0.9%
of the EPA limit 2 µg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2019
Highest in the city: 0.0400 µg/L — SBWJA GROVE PARK · 185 people · 2019
2/7 SYR4
PFOS
0.0051 µg/L
No EPA limit set
Highest in the city: STATE CORR INST BENNER TWP · 2,850 people · 2024
1/7 UCMR-5
Lead
0.0046 mg/L 31%
of the EPA limit 0.0150 mg/L
Main supplier: BELLEFONTE BOROUGH WATER AUTH · 9,500 people · 2025
4/7 LCR
PFHXS
0.0042 µg/L
No EPA limit set
Highest in the city: SPRING TWP WATER AUTHORITY · 3,300 people · 2023
1/7 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Bellefonte

Frequently asked questions about Bellefonte tap water

Is Bellefonte tap water safe to drink?

EPA testing detected 27 contaminants in the water serving Bellefonte. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Bellefonte?

7 public water suppliers report drinking-water monitoring for Bellefonte, Pennsylvania to the EPA. Each is listed above with its population served.

What contaminants are in Bellefonte's water?

The contaminants EPA monitoring detected in Bellefonte include Nitrate, Copper, Barium, Fluoride, TTHM. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.